P30
Readable Data
Modbus TCP Programmers Guide V1.02
14
© KEBA
Value 230: The measured voltage value on phase 3 is 230 V.
3.15
1046 - Power factor
This register contains the current power factor (cos phi) in 0.1 %.
Index
Name
Type
Attr.
1046
PF
UINT32
ro
Example:
Value 928: The measured power factor (cos phi) is 92.8%.
3.16
1100 - Max charging current
This register contains the maximum charging current of the charging station.
Unit: mA
Index
Name
Type
Attr.
1100
Max Current
UINT32
ro
Example:
Value 10000: The maximum charging current of the charging station is
10000 mA = 10 A.
3.17
1110 - Max supported current
Information
Socket variants show value 6000 mA as long as no cable is plugged into
the charging station.
This register contains the maximum current value that can be supported by
the hardware of the charging station. This value represents the minimum of
the DIP switch settings, cable coding and temperature monitoring function.
Unit: mA
Index
Name
Type
Attr.
1110
Curr HW
UINT32
ro
Example:
Value 10000: The maximum current value supported by the charging station
is 10000 mA = 10 A.