Configuration
The device is configured using the charging station: with DIP switches for
the P30 c-series and with the web interface for the P30 x-series.
The DIP switches on the charging station must be set as follows:
DIP switch
Setting
DSW1.2
OFF
DSW1.3
ON
The following settings must be configured in the web interface of the charg-
ing station:
1) Call up the web interface at: https://kecontact.web.UI.at
2) On the "Charging Network" tab, go to the "Phase switching" menu item.
3) Switch "Dynamic switching 1-phase/3-phase charging operation" to
"ON". "X2 connection status" switches to "Active" here.
4) Select "Communication channel" in the dropdown menu.