KC-P30
Authorization
Operating instructions V3.26
18
© KEBA
Information
If RFID cards have previously been taught in, they will be deleted in the
course of the teaching-in procedure!
To teach in the RFID master card, proceed as follows:
1) Remove the housing cover and connection panel cover to access the
service button (see
5.2.1 Preparing the charging station
).
2) Hold the service button pressed in the connection panel until the second
signal tone sounds (approx. 10 seconds).
The charging station now performs a restart automatically.
3) Immediately after rebooting the charging station, an RFID master card
must be taught in within 60 seconds by holding it in front of the RFID
reader.
A successful teaching-in process is confirmed by a signal tone.
Information
After teaching in the RFID master card, the LED bar flashes green for a fur-
ther 60 seconds and a charging session authorized by the RFID master
card can be started. After this, the LED bar flashes blue to indicate that au-
thorization to start a charge is required.
5.2.3
Teaching in the slave card
The RFID slave card can be used to authorize a charging process. The
RFID master card is required to teach in an RFID slave card.
No charging session may be active for the teaching in and no vehicle may
be connected to the charging station. The LED bar must flash blue.
To teach in the RFID slave card, proceed as follows:
1) Hold the RFID master card in front of the RFID reader until a signal tone
sounds.
2) Within 3 seconds hold the new RFID slave card to be taught in front of
the RFID reader. A successful programming process is confirmed by a
rising tone sequence.
3) Confirm the teach-in process within 3 seconds by holding the RFID mas-
ter card in front of the RFID reader again. The procedure is concluded
by a further rising tone sequence.
The LED bar then flashes blue to indicate that authorization to start a charge
is required.