6
1
Name: Basis
KEB COMBIVERT F4-F
14
16.03.99
Fucntional Description
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Section
Page
Date
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
201Fh
1
h
-
65535
0
2020h
1
h
-
65535
0
2023h
1
-
-
1
0
Adr.
min
max
default
2024h
1
inc
-
65535
0 (-65535)
ru-Parameter
ru.35 Actual position sign
Only active with activated positioning module!!! At decimal positioning display (Pc.1 = 0 or 1) it shows the sign of the
actual position. At hexadecimal display (Pc.1 = 2 or 3) the parameter is without function.
0:
Actual position in positive direction from zero point
1:
Actual position in negative direction from zero point
2:
without function since hexadecimal display is selected
(Standard setting zero point = reference point)
ru.31 Power on counter
The operating hours meter 1 displays the time the inverter was switched on. The indicated value includes all operating
phases. On attaining the maximum value (approx. 7.5 years) the display remains on the maximum value.
ru.32 modulation on counter
The operating hours meter 2 displays the time the inverter was active (motor controlled). On attaining the maximum
value (approx. 7.5 years) the display remains on the maximum value.
ru.36 Actual position high
Only active at activated positioning module!!! Indicates the absolute actual position of the reference point. Depending
on Pc.1 following representation is possible:
When display in increments (Pc.1 = 0 or 1) the displayed value must be multiplied with 10000 Inc.
When display in rotations (Pc.1 = 2 or 3) the displayed value is correspond to coplete motor rotations.
depend on Pc.1