3.2 Parameterization data (asynchronous objects)
It is not necessary that the COMBIVERT G6 has synchronized to the fieldbus cycle to
receive asynchronous requests and respond.
The parameter data are communicated via the handshaking shown in chapter
process data (manager => client)“
. The VARAN master has to write on to the area "acy-
clic request" at the DPM. The area "acyclic respond" is filled by the device with valid data
and can be read by the master.
The format of the subindex adressing is also described in chapter
examples of the byte Cmd/MsgID:
Initialisation:
0 0 1 1 1 1
1
1
(3Fh)
Read access:
0 0 0 1 0 0
0
0
(10h)
Write access:
0 0 1 0 0 0
0
1
(21h)
The number of successfull asynchronous communication accesses are shown in the
following parameters.
Id-Text
Name
Parameter index
fb20
Master write event counter
0x2194
Meaning
Number of asynchronous write accesses
Type
Variable
Data length
16 bit
Access
read / write
Coding
0...65535
Standard value: 0
Note
-
11
DUAL PORT MeMORy