4 Process Data Mapping
The setting of the process data assignment can be done in two different ways. One is
through the KEB specific parameters (fb10-fb19), on the other hand about the parame
-
ters (co08, c014) which are defined according to the CAN DS301 profile.
After successful adjustment of the process data mapping the process data can be pro-
cessed by the G6 device.
4.1 Output process data (manager
=
>
client)
Id-Text
Name
Parameter index
fb10
PD out index
0x218A
Type
Array
Subindex 0
Meaning
Number of subindices of this object
Data length
8 bit
Access
read
Coding
8
Standard value: 8
Note
-
Subindex 1...8
Meaning
Default up to 8 parameter addresses to be used as process
data. Only parameters may be used that are allowed as process
data. The value corresponds byte 2 and 3 of the DS301 param-
eter co08.
Data length
16 bit
Access
read / write
Coding
0000h…FFFFh
Standard value: 0000h
Note
-
13