56
DIMeNSIONS AND WeIGHTS
3.5.3 Push-through version IP54
305
7,5
150
77,5
320
75
145
160
M5
36
290
15
27
*
*
*
*
80
165
130
1,25
292
132
75
150
305
145
77,5
6,5
ST
ST
OPT
DEV
NET VCC
ST
FS
Housing
2
Weight
5.2 kg
Dimensions
All dimensions in mm
*
Optional shield connection braket
Figure 11:
Dimensions push-through version IP54
IP54 zone: Heat sink underneath the mounting plate
For proper installation, the enclosed seal (20F6T45-0001) must be installed
between heat sink and housing (e.g. cabinet wall). The tightness must be
checked after the installation. If properly installed, the separation to the housing
corresponds to degree of protection IP54. However, the fans must be protected
against unfavorable environmental influences. These include combustible, oily
or dangerous fumes or gases, corrosive chemicals, coarse foreign bodies and
excessive dust. This applies especially to the access of the heatsink from the
top (air outlet). Icing is inadmissible.
IP20 zone: Device above the mounting plate
Power connections excluded
=> „Climatic environmental conditions“
“. This part
is intended for the installation in a suitable housing for the required degree of
protection (e.g. control cabinet).
UL: Device heat sink is classified as NEMA type 1.
Содержание COMBIVERT 10F6 Series
Страница 2: ......
Страница 82: ...82 NOTES...