41
DeVIce DATA OF THe 400 V DeVIceS
3.3.3 Input and output currents / overload for 400 V devices
Device size
12
13
14
15
16
Rated input current @
U
N
=
400V
I
in
/ A
13
17
21
31
43
Rated input current @
U
N_UL
=
480V
I
in_UL
/ A
11
15
18
27
35
Table 25:
Input currents of the 400 V devices
1)
The values resulting from rated operation with B6 rectifier circuit and mains choke 4% U
k
.
Device size
12
13
14
15
16
(2 kHz)
16
(4 kHz)
Rated output current
@
U
N
=
400V
I
N
/ A
9.5
12
16.5
24
33
Rated output current
@
U
N_UL
=
480V
I
N_UL
/ A
7.6
11
14
21
27
Rated output overload (60 s)
1)
I
60s
/ %
150
Overload current
1)
I
OL
/ %
=> „Overload characteristic (OL) for 400 V devices“
Software current limit
2)
I
lim
/ %
180
150
Overcurrent
1)
I
OC
/ %
216
180
Table 26:
Output currents of the 400 V devices
1)
The values refer in % to the rated output current I
N
.
2)
Limitation of the current setpoint in closed-loop operation. This setpint limit is not active in v/f op
-
eration.
3.3.2.1 Example of the calculation of the possible motor voltage:
The motor voltage for dimensioning of the drive is depending on the used components.
The motor voltage reduces according to the following table:
component
reduction / % example
Mains choke U
k
4
Example:
open-loop drive converter with mains- and motor choke at
non-rigid supply system:
400 V mains voltage - 11 % = 356 V motor voltage
Drive converter open-loop
4
Drive converter closed-loop
8
Motor choke U
k
1
Non-rigid supply system
2
Table 24:
Example of the calculation of the possible motor voltage: