5.1.1 Installation
Figure 13 Bolt Removal
1. Using a 17mm wrench/socket, remove the two standard bolts (1) from the magnet
assembly as shown above.
2. Mount the hand release yoke (2) to the magnet using the spherical bolts and washers
included with the kit as shown below.
Figure 14 Hand Release Yoke Attachment
3. Tighten the bolts to 60Nm with a 13mm wrench/socket.
4. Screw the hand release handle (3) to the yoke, ensuring a tight fit.