background image

24

 SySTEM  DESCRIPTION

2.4.4  KEB Remote Video Link

C6 E22 BM-RVL integrates all the circuitry that allows the DVI-D and USB 2.0 signals to 

be reliably transmitted to a monitor up to 100 m away using a Cat 5e SF/UTP or Cat 6A 

SFTP (Shield Foil Twisted pair) cable.

The remotation system is composed by C6 E22 BM-RVL and a KEB industrial monitor 

C6 Monitor or C6 AMM that integrates the RVL receiver section.

Cat 5e SF/UTP

Cat 6A S/FTP

up tp 100 mt

C6 Monitor 

with integrated remotation

REMOTATION 

CABLE

Figure 8: 

Remote Video Link detail

Cat 5e SF/UTP

Cat 6A S/FTP

up tp 100 mt

C6 AMM

with integrated remotation

REMOTATION 

CABLE

Figure 9: 

Remote Video Link detail

Содержание C6 E22 BM

Страница 1: ...BOOK MOUNT IPC INSTRUCTIONS FOR USE C6 E22 BM C6 E22 BM RVL Original Manual Document 20170810 EN 01...

Страница 2: ......

Страница 3: ...in case of non observance of this safety instruction WARNING Dangerous situation which may cause death or serious injury in case of non observance of this safety instruction CAUTION Dangerous situati...

Страница 4: ...get products is beyond of our control and therefore exclusively the responsibility of the machine manufacturer system integrator or customer The information contained in the technical documentation as...

Страница 5: ...14 1 3 Installation 15 1 4 Electrical connection 15 1 5 Start up and operation 16 1 6 Maintenance 16 1 7 Preventive Maintenance 16 1 8 Disposal 17 2 System Description 18 2 1 Key features 18 2 1 1 Is...

Страница 6: ...Start up 43 4 1 Additinal notes for Windows Embedded Standard 7 43 4 2 EWF implementation in the Windows Embedded Standard 7 images 43 5 KEB Write Filter Manager 44 5 1 Introduction 44 5 2 How EWF wo...

Страница 7: ...tents 7 2 1 Power supply technical data 57 7 2 2 System power consumption 58 7 3 Battery technical data 58 7 4 Technical support and repairs 59 8 Certification 60 8 1 Mark of conformity 60 8 2 UL cert...

Страница 8: ...gure 19 Labels postion 31 Figure 20 C6 E22 BM 33 Figure 21 C6 E22 BM 34 Figure 22 C6 E22 BM 34 Figure 23 Wall mounting procedure 35 Figure 24 Wall mounting procedure 35 Figure 25 Wall mounting procedu...

Страница 9: ...t pending boot commands 50 Figure 51 Battery installation removal 51 Figure 52 Battery installation removal 51 Figure 53 Battery installation removal 51 Figure 54 Battery installation removal 51 Figur...

Страница 10: ...of Tables Table 1 Micro UPS data 30 Table 2 Protectable Volumes 44 Table 3 Technical data 55 Table 4 Options 56 Table 5 Power supply technical data 57 Table 6 System power consumption 58 Table 7 Batt...

Страница 11: ...he KEB I O EtherCat system HMI Human machine interface touch screen IEC International standard IP xx Degree of protection xx for level KEB I O EtherCAT SPS Small control system from the KEB I O system...

Страница 12: ...e systems Part 1 Princi ples requirements and tests IEC 60664 1 EN60721 3 1 Classification of environmental conditions Part 3 1 Classification of groups of environmental parameters and their severitie...

Страница 13: ...8 1 7 Functional safety of electrical electronic programmable electronic safety related systems Part 1 7 VDE0803 1 7 IEC61508 1 7 EN61800 2 Adjustable speed electrical power drive systems Part 2 Gener...

Страница 14: ...lowing qualifications Knowledge and understanding of the safety instructions Knowledge of automation technology Knowledge of functional safety Skills for the installation and assembly of electrical eq...

Страница 15: ...s etc This also applies to mechanical components which can lose small parts during operation Check the reliable fit of the device connections in order to minimize contact resist ance and avoid sparkin...

Страница 16: ...losed Use only approved accessories for this device Never touch terminals busbars or cable ends 1 6 Maintenance The following maintenance work has to be carried out when required but at least once per...

Страница 17: ...ng so called B2B devices Thus the marking does not occur with the symbol of the crossed out wheeled bin but by the word mark and the date of manufacture Unlike devices mainly used in private household...

Страница 18: ...y unit with galvanic isolation Micro UPS are described in a separate part C6 E22 BM as an alternative to the DVI I output can integrate the KEB Remote Video Link providing remotation of DVI I and USB...

Страница 19: ...e at low medium frequencies on the power supply line Ground loop noise Extra voltage caused by lightning Power supply with grounded positive terminal e g Japan Figure 1 Isolated Power Supply 2 2 Packa...

Страница 20: ...cription 2 3 Front Compact solid and robust full aluminium Figure 3 Front detail 2 4 Rear The back of the system is made of a full aluminium plate 1 1 1 1 2 1 Fixing holes 2 Rear fixing plate Figure 4...

Страница 21: ...scription 2 4 1 Connectors To access the connectors it is necessary to open the frontal flap 1 2 3 4 5 1 Front door 2 USB 3 0 connector 3 Battery slot 4 CFAST slot sata2 5 Opening handle Figure 5 Conn...

Страница 22: ...ription 2 4 2 Top Connectors 1 1 2 3 4 5 6 7 1 Battery pack connector 2 Power DC input connector 3 DVI I connector 4 LAN1 connector 5 LAN2 connector 6 USB2 connector 7 USB1 connector Figure 6 Top conn...

Страница 23: ...4 3 RVL Top Connectors LED 1 3 2 4 5 6 7 8 1 Battery pack connector 2 Power DC input connector 3 RVL LINK LED 4 RVL OUT 4 LAN1 connector 5 LAN2 connector 6 USB2 connector 7 USB1 connector Figure 7 To...

Страница 24: ...Shield Foil Twisted pair cable The remotation system is composed by C6 E22 BM RVL and a KEB industrial monitor C6 Monitor or C6 AMM that integrates the RVL receiver section Cat 5e SF UTP Cat 6A S FTP...

Страница 25: ...LED signaling area Figure 10 LED signaling detail 1 2 3 4 5 6 7 1 Power on LED 2 UPS LED 3 HDD activity LED 4 Over temperature Battery fault LED 5 Watchdog Reset factory default LED 6 PLC status LED 7...

Страница 26: ...Description 2 4 6 Buttons Area 1 1 Buttons area Figure 12 Buttons area detail 1 2 3 4 5 1 Power on rest 2 System reset 3 Watchdog reset 4 Factory default reset 5 PLC Run Stop Reset Figure 13 Buttons a...

Страница 27: ...7 Power Supply Earth Screw 1 2 1 Earth screw 2 Power supply area Figure 14 Power Supply area detail 1 1 Earth screw Figure 15 Power Supply area detail 1 UPS connector 2 Power supply socket Figure 16...

Страница 28: ...Description 2 4 8 Battery CR2032 3V 1 1 Battery Figure 17 Battery slot detail DANGER Risk of explosion If the battery is replaced with an incorrect type Dispose of used batteries according to the ins...

Страница 29: ...formance and the security features as data reliability in case of a sudden power off required for an industrial application WARNING Removing the system memory card while the project is running If you...

Страница 30: ...psed the system checks again the UNDER_VOLTAGE If the signal is still active the system checks for the MICRO_UPS_VCAP_OK If this signal is high the super capacitors are ready and the peripherals are s...

Страница 31: ...Description 2 4 11 Labels position On the lateral panel the following label is present 3 2 1 4 5 1 Model 2 CE marking 3 Material number 4 COMBIVIS connect license 5 COMBIVIS HMI license Figure 19 Labe...

Страница 32: ...ng sections a Certificates and approvals b Electromagnetic compatibility Check the mechanical and climatic ambient conditions for operation of the device Follow the instructions for local use of the d...

Страница 33: ...33 Installationand connection 3 6 Dimensions 3 6 1 C6 E22 BM 5 5 208 5 6 220 18 35 18 18 35 18 71 4 5 4 2 Figure 20 C6 E22 BM...

Страница 34: ...34 Installationand connection 19 182 19 220 Figure 21 C6 E22 BM 71 159 5 Figure 22 C6 E22 BM...

Страница 35: ...crew n 4 fixing screws Drill the required holes on the housing panel wall according to the instructions detailed in paragraph 3 6 Dimensions There are 4 fastening points Fastening can be made using st...

Страница 36: ...ionand connection Align the bottom Figure 25 Wall mounting procedure Release the top to match the slots with the screws Figure 26 Wall mounting procedure Tighten the four screws Figure 27 Wall mountin...

Страница 37: ...the interface To overcome this hazard such current must be steered away from the interface To achieve this goal the following methods can be used Figure 28 Power supply diagramm 1 Use an equipotentia...

Страница 38: ...ature has many benefits Increases the noise immunity of the system Avoids input short circuits in systems with the power supply grounded Breaks ground loops which may cause interferences in the video...

Страница 39: ...onnector cup to be installed on the two poles power connector To properly assemble the connector please follow these instructions Figure 32 Power connector assembly Insert the cable tie in the cup as...

Страница 40: ...tor in the cup as shown in the picture Figure 35 Power connector assembly Tighten the cable tie Figure 36 Cup installation Cut the excess part Figure 37 Cup installtion Insert the white label and clos...

Страница 41: ...e extra low voltage SELV in accordance with IEC EN DIN EN UL60950 1 Remove the two poles plug connector from the system the system is shipped with the power plug connected Always check that the voltag...

Страница 42: ...e 41 Power on sequence The system begins bootstrap 3 9 Shutdown To shut down the system please follow the standard procedure of your operating sys tem After power down procedure is completed the syste...

Страница 43: ...the EWF protected volumes on the device including the number and sizes of protected volumes and overlay levels Only one EWF volume is created on your device regardless of how many disks are in the sy...

Страница 44: ...picture remains unchanged When EWF is enabled for a volume every write operation to that volume will be redirec ted to an overlay in RAM and no data will be persistently stored into the volume In case...

Страница 45: ...ges to C will be committed Otherwise they will be discarded after a reboot The following table shows the dependencies between the volumes Legend x Possible Not possible x1 Possible but EWF enabled aga...

Страница 46: ...active the EWF for volume C by clicking Yes The device will reboot immediately and the EWF is enabled for volume C If you click No the message box is closed but will be appear again after the next reb...

Страница 47: ...pears with volume C preselected in the following view assuming that EWF for volume C has been enabled by the message box already before Figure 46 Program s GUI Under the Volume you see the states of t...

Страница 48: ...data to the EWF protec ted volume and then disabled EWF This function does NOT require a reboot NOTICE All changes on the volume since the last reboot become effective Do not execute this if you are...

Страница 49: ...lume C is necessary The following message box asks if the Commit command for C should also be set It is recommended to confirm with Yes The message will not appear if the Boot Command for C Commit alr...

Страница 50: ...he Exit button In this case the program checks for pending boot commands and shows if appropriate the following message box Figure 50 Neglect pending boot commands It is recommended to choose Yes to e...

Страница 51: ...supply Using a screwdriver not provided carefully pull out the battery holder Figure 51 Battery installation removal Figure 52 Battery installation removal Remove the battery and replace it with one o...

Страница 52: ...e way 6 2 1 Removal Figure 56 CFast installation removal Push and release the memory card as indicated in the figure Extract the memory card from the slot 6 3 Maintaining and cleaning C6 E22 BM is des...

Страница 53: ...th this handle questions on the entire range of products skillfully quickly and efficiently You can phone our staff in the service department and they will give you complete prompt advice on how to re...

Страница 54: ...54 Technical specifications 7 Technical specifications 7 1 Block Diagram Figure 57 Block diagram...

Страница 55: ...uantity is automati cally selected by operating system max 1720 MB System memory DDR3 1066 type 1 SODIMM module min 1GB max 8GB Mass storage interfaces 1 x SATA 2 3Gb s or 1 x mSATA 2 3Gb s Front sign...

Страница 56: ...0 1000Mpbs Intel I210 External Monitor Output DVI I Single Link video interface for additional external monitor Max resolution 1920x1080 FullHD VGA ad apter included Remote Video Link integrated remot...

Страница 57: ...4A SMD The fuse can be replaced only in factory Power supply Type Isolated DC DC Isolation voltage 500 VAC Input voltage 18 32V DC Input protection Reverse polarity circuitry Overvoltage 4A soldered f...

Страница 58: ...1080 FullHD VGA adapter included 0 0 Remote Video Link integrated remo tation up to 100m of DVI I video signals and USB 2 0 without cables note 1 4 1 SSD mSATA SSD mSATA SATA 2 2 0 CFAST CFast SATA 2...

Страница 59: ...mplete after sales technical support The staff who deal with this handle questions on the entire range of products skilfully quickly and efficiently You can phone our staff in the service department a...

Страница 60: ...y 24 Vdc The above given product is in accordance with the following directives of the European Union Number EMC 2014 30 EU Text Directive on the approximation of the laws of the Member States relatin...

Страница 61: ...61 Certification...

Страница 62: ...62 Certification 8 2 UL certifications Acceptance according to UL is marked at KEB inverters with the adjacent logo on the type plate...

Страница 63: ...E Mail info keb it Internet www keb it Japan KEB Japan Ltd 15 16 2 Chome Takanawa Minato ku Tokyo 108 0074 Japan Tel 81 33 445 8515 Fax 81 33 445 8215 E Mail info keb jp Internet www keb jp P R China...

Страница 64: ......

Отзывы: