Lighting Problems Trouble Shooting
• #1
- Check millivolt output with Voltmeter
or Multi-meter
– With thermostat contacts open, 325 to
700 mV.
– With thermostat contacts closed, 200 mV
or more.
– If readings are below the numbers listed,
replace thermopile.
PROBLEM:
Pilot lights, but will not stay lit