background image

D   

052505   Grease Drawer (Not Shown)

8

VI PARTS LIST

ORDERING PARTS

Parts may be ordered by calling 1-800-KEATING or your local Keating service company.  You may also order on-
line at Keating’s part store, www.keatingofchicago.com

Refer to the Keating MIRACLEAN

®

Electric Griddle Limited Warranty for complete service and ordering

information.

The model/serial plate is located inside of the grease drawer area to the left or on the front of the upper heat shield
above the control panel. The serial and model numbers are necessary when ordering.

WARNING AND OPERATING PLATES

All warning and operating plates on the Keating MIRACLEAN

®

Electric Griddle should be in place at all times. If plates are

damaged or lost, replace them immediately.

A

B

A

C

B

C

*E

D

Part No. Description

A

035954

Thermostat 400°F

029521

Thermostat 550°F

034870

Thermostat Dial Plate 400°F

060105

Thermostat Dial Plate 550°F

004163

Thermostat Knob 400°F

038267

Thermostat Knob 550°F

B

050255

Light

C

054920

Switch

D

052505

Grease Drawer

002457

Grease Drawer for Model 32 A only

*E

Not shown on this page. See page 9.

A

B

B

Part No. Description

A

037392

Thermostat with Sleeving & Light

037391

Thermostat with Sleeving & Black Knob

002621

Indicating Light White

014983

Thermostat Knob 200°-550°F Black

B

052505

Grease Drawer

Part No. Description

A

004157

Amber Indicating Light, 220 Volt

B

060354

Toggle Switch, 30 Amp 250 Volt

C

029521

Thermostat 550°F

060105

Thermostat Dial Plate 550°F

030267

Thermostat Knob 550°F

CONTROL PANEL 208 - 240 VOLT

2011 CONTROL PANEL 208 - 240 VOLT

CONTROL PANEL 480 VOLT

C

OT

F

A

T

B

IL R A

I

E S H

T

2502

5

0

200 20

0

4504

50

350

350

300

300

400

400

500 500

C

OT

F

A

T

B

IL R A

I

E S H

T

2502

5

0

200 20

0

4504

50

350

350

300

300

400

400

500 500

ON

OFF

ON

OFF

Содержание Griddle

Страница 1: ...LY 9 STAND ASSEMBLY 10 WIRING DIAGRAMS 11 14 24 DEEP MODELS 15 30 DEEP MODELS 16 36 DEEP MODELS 17 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty per...

Страница 2: ...E VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OP...

Страница 3: ...Electrical Code CAN 22 2 as applicable Your ventilation hood when installed must conform to the current ANSI NFPA 96 standard Installation clearance requires 6 from rear and side walls You must mainta...

Страница 4: ...the current ANSI NFPA 96 standard ALL connections and placement must comply with local and national codes It is the responsibility of the owner and local installer to comply with these regulations whe...

Страница 5: ...be found on its serial number tag Consult the National Electrical Code Handbook for additional information or to help answer questions about wire size selection For runs greater than 75 up to 125 use...

Страница 6: ...ement of elements under MIRACLEAN plate 5 After each load scrape the griddle surface completely clean using the 4 wide replaceable blade scraper NOTE DO NOT HACK CHOP HIT OR CUT ON THE MIRACLEAN SURFA...

Страница 7: ...40 Volt Unit Turn each thermostat fully counterclockwise and On Off switch to OFF position For 480 Volt Unit Turn thermostat knob to OFF position IV MAINTENANCE WARRANTY REPAIRS Keating s warranty beg...

Страница 8: ...position Place thermometer on plate over bulb half way toward rear of griddle Figure 4 1 Thermostat calibration 4 If calibration of griddle is found to be less than 50 F off simply loosen four dial p...

Страница 9: ...wer b Reset circuit breakers External c Set On Off switch to ON position d Turn thermostat to desired cooking temperature e Replace On Off switch f Replace thermostat g Tighten connections h Replace e...

Страница 10: ...rmostat 400 F 029521 Thermostat 550 F 034870 Thermostat Dial Plate 400 F 060105 Thermostat Dial Plate 550 F 004163 Thermostat Knob 400 F 038267 Thermostat Knob 550 F B 050255 Light C 054920 Switch D 0...

Страница 11: ...20V HIGH INPUT 002480 1 3000W 440V 013270 1 3750W 480V 006337 1 3300W 480V 005567 1 WASHER FLAT 10 7 16 OD 059502 2 2 2 WASHER LCKG INT TOOTH HI TEMP 10 011562 4 4 4 NUT 10 32 000361 2 2 2 2 HEAT DISP...

Страница 12: ...10 Assembly instructions for griddle stand on casters There is no top on this stand...

Страница 13: ...VII WIRING DIAGRAM 208 240 VOLT WIRING DIAGRAM 2011 ORG BLK BLK BLK thermostat RED TO TH TP ON GAS VALVE WHITE TO TP TERMINAL ON GAS VALVE TO TH ON GAS VALVE TO TH TP ON GAS VALVE TO PILOT ON GAS VAL...

Страница 14: ...12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Страница 15: ...208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS 13...

Страница 16: ...14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Страница 17: ...08 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 AMPS PER LINE THREE PHASE 3 ELEMENTS 2300 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 3 26 34 26 49 220 11 5 28 36 28 52 240 13 7 30...

Страница 18: ...LTS kW SINGLE L1 L2 L3 PHASE 208 13 4 34 45 34 65 220 15 0 36 47 36 68 240 17 9 39 52 39 74 AMPS PER LINE THREE PHASE 5 ELEMENTS 3000 W EACH 60x30 A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 7 34 34...

Страница 19: ...30 68 240 17 9 49 49 32 75 AMPS PER LINE THREE PHASE 4 ELEMENTS 3750 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 16 8 43 56 43 81 220 18 8 45 59 45 85 240 22 3 49 64 49 93 AMPS PER LINE THREE PH...

Страница 20: ...08 10...

Страница 21: ...__________________________________________________________________________________ ADDRESS ______________________________________________________________________________________________________ CITY _...

Отзывы: