PROBLEM

PROBABLE

SOLUTION

CAUSE

Motor does not operate.

1.

No electrical power to filter.

1.

Verify electrical power is available to filter.

2.

Motor overload tripped.

2.

Turn filter switch to “OFF” then pull-on 
motor overload reset lever located in filter 
cabinet.

3.

Open wiring.

3.

If motor operates and then overload trips
again, check for filter line blockage. If motor
does not operate, check wiring for continuity.

4.

Defective motor or switch.

4.

Replace defective motor/pump or switch. 

Filter operates slowly

1.

3-way return valve not 

1.

Make sure valve handle is in correct 

or spurts.

closed properly or in wrong

position.

position.

Refer to filtering instruction card.

2.

Incorrect operating procedure.

2.

Verify proper operating procedure.

3.

Air leak in piping.

3.

Verify quick disconnect is fully engaged, all
piping connections are tight and hoses are not
cracked and leaking. Tighten connections or
replace defective hoses. 

Oil does not pump

1.

Air leak in piping.

1.

Verify quick disconnect is fully engaged, 

completely out of 

all piping connections are tight and hoses 

filter vessel.

are not cracked and leaking. Tighten 
connections or replace defective hoses. 

2

.

Filter paper totally clogged.

2

.

Replace filter paper and apply Acidox Powder
being sure to use only one sheet of filter paper
and proper quantity of Acidox Powder for filter
model.

3

.

Hold down ring not completely

3

.

Verify position of paper and proper size. 

sealing filter paper and air is 

Use correct paper size and confirm seal. 

being drawn into pump.

PREVENTIVE MAINTENANCE:

1.

To remove water, stir oil until oil bubbling stops; water will clog filter paper pores.

2.

Verify all connections, especially quick disconnect, are tight; not leaking oil or sucking air.

3.

Use only one sheet of filter paper properly sealed under hold down ring.

4.

Use a drain clean out rod if partial or full blockage in fryer drain is suspected.

5.

If filter was used for fryer boil out, run oil through filter to lubricate motor/pump.

6.

Clean filter after each use. Do not permit oil to remain in filter drawer; it will clog motor/pump.

7.

Verify all lights and controls operate.

8.

Adhere to operating instructions in sequence given for proper filtration.

9.

Prepare filter for next use by using new filter paper and Acidox Powder.

TROUBLESHOOTING GUIDE

Содержание Central Filter Hands Free

Страница 1: ...edge to edge from front to back overlapping on sides Filter Paper must be smooth and flat under hold down ring to get a proper seal NOTE One package of Acidox is needed for every 40 pounds of oil 7 Sp...

Страница 2: ...t pump switch to MELT position for ten minutes to melt any solidified shortening in the return pipe only on models with melt cycle 5 Let the pump run with drain valve open to remove crumbs and residue...

Страница 3: ...strainer basket and cover push drawer fully into cabinet and reconnect intake hose Check to ensure proper connection 10 Close the cabinet door NOTE Instructions for cleaning the fryer are in the Opera...

Страница 4: ...er brush may be used to scrub the tubes elements and inside walls of fryer Pump the water and Sea Powder into a dry suitable receptacle and remove from cooking area Sprinkle Keating Klenzer liberally...

Страница 5: ...for CF24 Filter Drawer not shown 023206 Caster for Cradle without brake not shown 020866 Caster for Cradle with brake not shown 012160 10 Intake Hose 000652 Intake Hose with Quick Disconnect 020023 11...

Страница 6: ...ions are tight and hoses filter vessel are not cracked and leaking Tighten connections or replace defective hoses 2 Filter paper totally clogged 2 Replace filter paper and apply Acidox Powder being su...

Страница 7: ...Tel 708 246 3000 Fax 708 246 3100 Toll Free 1 800 KEATING www keatingofchicago com If you have any questions regarding filtering procedures or need assistance call 1 800 KEATING Central Filter pre2000...

Страница 8: ...SE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installa...

Страница 9: ...___________________________________________________________ INVOICE NUMBER ____________________________ SERIAL NUMBER ________________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS _____...

Отзывы: