12
Check point after installation
The wiring is connected properly to the
power supply.
Pemeriksaan selepas pemasangan
Pendawaian bersambung secara betul
kepada bekalan kuasa.
㓺㻻ⲺỶ僂⛯
电线已正确地连接了电源线。
WARNING
Electrical wiring must be done
by a quali
fi
ed individual.
Can cause
fi
re or electrical shock.
This product is not provided
with a cord and plug or with
other means for connection to
the supply.
When connecting or changing
the power cord or lead wire,
it must be performed by a
quali
fi
ed person in order to
avoid a hazard.
Please use 227IEC53(RVV)
or thickness of tube 1 mm
or above. (If there are other
requirements such as the
diameter of lead wire, please
use according to the regulation
of the country).
Can cause
fi
re or electrical shock.
Do not bypass and short circuit
the Safety Switch.
Can cause
fi
re, electrical shock,
injury or Ceiling Fan to drop.
AMARAN
Pendawaian elektrik mesti
dipasang oleh orang yang
bertauliah.
Boleh menyebabkan kebakaran
atau kejutan elektrik.
Produk ini tidak dilengkapi
dengan wayar dan palam
atau apa-apa yang boleh
memutuskan sambungan
dengan bekalan kuasa. Untuk
mengelakkan sebarang
kecederaan, pemasangan wayar
dan palam mesti dilakukan
oleh orang yang berkelayakan.
Gunakan 227IEC53(RVV) atau
tiub yang berketebalan lebih
dari 1 mm. (Keperluan lain
seperti diameter wayar, sila
gunakan mengikut peraturan
negara-negara berkenaan).
Boleh menyebabkan kebakaran
atau kejutan elektrik.
Jangan pintas dan litar pintas
Suis Keselamatan.
Boleh menyebabkan kebakaran,
kejutan elektrik, kecederaan atau
Kipas Siling terjatuh.
䆜
⭫㓵䞃㓵ᐛ֒ᗻ亱⭧ᴿ䍺Ṳ
ⲺӰ䘑㺂Ⱦ
可能会导致火灾或触电。
ᵢӝуᨆב⭫㔼ૂᨈཪᡌ䘔⭫
ⓆⲺެᆹ㻻㖤Ⱦ
䘔ᡌᴪᦘ⭫㔼ᡌ⭫㓵ᰬᗻ亱⭧ᴿ
䍺ṲⲺӰ䘑㺂ԛ䚵ރধ䲟Ⱦ
䈭ֵ⭞
227IEC53(RVV)
ᡌᓜ䎻
䗽
1
∡㊩
Ⲻሲ㇗Ⱦδެᆹ㾷≸θ
ׁྸ⭫㓵ᖺㅿㅿθ䈭䚫ᆾީള
ᇬⲺᶗׁεȾ
可能会导致火灾或触电。
࠽वሯᆿޞᔶީ䘑㺂㔋䚉ૂ⸣䐥Ⱦ
可以导致火灾、触电、受伤或吊
扇掉落。
Dimmer switch /
Suis ‘dimmer’ /
调光开关
Regulator /
Pengawal Kelajuan /
调节器
Power supply /
Bekalan kuasa elektrik /
电源
Connect directly /
Penyambungan terus /
直接连接
Dimmer switch /
Suis ‘dimmer’ /
调光开关
Power supply /
Bekalan kuasa elektrik /
电源
Connect directly /
Penyambungan terus /
直接连接
Regulator /
Pengawal Kelajuan /
调节器
3
4
How to install
Cara pemasangan
ྸᆿ㻻
■
Attention:
1
It is recommended to user to install
OFF/ON switch on the wall for the
Ceiling Fan, replacing existing
regulator or new regulator point.
2
This product should be installed with
a double poles single throw switch
(breaker switch) with a minimum of 3
mm contact gap in the
fi
xed installation
circuit.
3
Do not use regulator or dimmer switch
for this model.
(It can damage the Ceiling Fan)
4
Should there be a regulator or dimmer
switch, disconnect it and reconnect the
wiring as above.
■
⮏ᝅφ
1
建议用户将吊扇的
OFF/ON
开关安装
在墙壁上、替换现有的调节器或新的
调节点。
2
此产品必须在固定安装电路上装上触点
间隙为最少
3
毫米
的双极单投开关(断
路开关)。
3
切勿使用调光开关或调节器。
(这会损坏吊扇)
4
若有调节器或调光开关、请按照上图拆
除然后重新连接。
■
Perhatian
φ
1
Pengguna disyorkan supaya memasang
suis TUTUP/BUKA di dinding untuk
Kipas Siling bagi mengganti pengawal
kelajuan lama atau titik pengatur baru.
2
Produk ini harus dipasang dengan
suis lontaran tunggal dwikutub (suis
permutus) dengan ruang sentuhan
sekurang-kurangnya 3 mm di litar
pemasangan tetap.
3
Jangan menggunakan suis ‘dimmer’
atau alat pengawal kelajuan.
(Boleh merosakkan Kipas Siling)
4
Sekiranya terdapat pemasangan
alat pengawal kelajuan atau suis
‘dimmer’, putuskan sambungannya
dan sambungkan semula pendawaian
seperti di atas.