![KDE Direct KDE-UAS40UVC Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/kde-direct/kde-uas40uvc/kde-uas40uvc_manual_659793017.webp)
REV 1.0.8 (Last Modified March 1, 2021)
17 | 30
R E V 1 . 0 . 8
2: Get Voltage (U16)
MASTER TO ESC:
Extended Frame ID
Priority
Source
Address
Destination
Address
Object
Address
0x00
0x00
0x02
0x02
ESC TO MASTER(Answer)
Extended Frame ID
Data
Priority
Source
Address
Destination
Address
Object
Address
Byte0
Byte1
0x00
0x02
0x00
0x02
V0
V1
Example:
Message
Transmission:
Frame ID:
Data:
Data Decimal Equivalent:
Data Description:
Master to ESC:
00 00 02 02
00 00 00 00 00 00 00 00
Requests ESC voltage.
ESC to Master:
00 02 00 02
06 2D
1581
1581 / 100 = 15.81 V
3: Get Current (U16)
MASTER TO ESC:
Extended Frame ID
Priority
Source
Address
Destination
Address
Object
Address
0x00
0x00
0x02
0x03
ESC TO MASTER(Answer)
Extended Frame ID
Data
Priority
Source
Address
Destination
Address
Object
Address
Byte0
Byte1
0x00
0x02
0x00
0x03
C0
C1
Example:
Message
Transmission:
Frame ID:
Data:
Data Decimal
Equivalent:
Data Description:
Current = #/100
Master to ESC:
00 00 02 03
00 00 00 00 00 00 00 00
ESC to Master:
00 02 00 03
00 4C
76
76 / 100 = 0.76 A
00 9D
157
1.57 A
00 A2
162
1.62 A
00 AA
170
1.70 A
00 AE
174
1.74 A