KDAR SPG Скачать руководство пользователя страница 12

 

KDAR Company 

15009 Manchester Rd. #283 

Ballwin, MO 63011-4626 

 

Phone: 314-692-8555   Fax: 314-692-8578 

Warranty 

KDAR Company, and its affiliates, warrants that 
the spool gun covered under this warranty is free 
from defects in material and workmanship for two 
years from the date of purchase. This warranty is 
extended to the original purchaser who uses the 
product in a consumer application (personal, resi-
dential or household usage). All welders covered 
under this limited warranty which are used in 
commercial applications (i.e. income producing) 
are warranted to be free from defects in material 
and workmanship for 2 Years from the date of 
original purchase when properly registered. The 
product covered under this warranty is the SPG 
Spool Gun. 
 
KDAR Company, and its affiliates, will repair or 
replace, at KDAR’s sole discretion, parts found to 
be defective in material or workmanship within 
the warranty period. Warranty service will be 
scheduled according to the normal work flow and 
business hours of the service center doing the 
work as well as the availability of replacement 
parts. All decisions from KDAR Company re-
garding this limited warranty shall be final. 
 

Original Purchaser’s Responsibility:

 

 
1.  Retain the original cash register receipt as 

proof of purchase. 

2.  Follow manual instructions regarding the care 

and operation of your welder. 

3.  If warranty work is required, 

DO NOT RE-

TURN THIS WELDER TO THE RE-
TAILER.

 Contact KDAR Company for in-

structions. Visit www.hotmaxtorches.com or 
call KDAR Company M-F 8AM-5PM CST to 
locate the nearest Authorized Service Center. 

Not Covered:

 

 
1.  Transportation charges for sending or deliver-

ing the welder to the Authorized Service Cen-
ter or returning the repaired or replacement 
welder back to the customer. These charges are 
the responsibility of the customer. 

2.  Damages caused by ordinary wear, abuse, rain, 

freeze damage, negligence, accident or failure 
to operate or maintain the welder in accordance 
with the instructions in the operator’s manual 
supplied with the welder. 

3.  Damage caused by unauthorized repair or al-

terations. 

 

Exclusions and Limitations:

 

 

KDAR Company makes no other warranty of 
any kind, express or implied. Implied warran-
ties, including warranties of merchantability 
and of fitness for a particular purpose, are 
hereby disclaimed. The warranty service de-
scribed above is the exclusive remedy under 
this warranty; liability for incidental and conse-
quential damages is excluded to the extent per-
mitted by law. 

 
This warranty gives you specific legal rights, and 
you may have other rights which vary from state to 
state. Some states do not allow a disclaimer of im-
plied warranties, or the exclusion of incidental and 
consequential damages, so the above disclaimers 
and exclusions may not apply to you. 
 

For warranty service or to obtain service parts 
or accessories:

 

 
Call: 314-692-8555 M-F 8-5 PM, CST 
Visit: www.hotmaxtorches.com 
Write: KDAR Company 
 

15009 Manchester Rd #283 

 

Ballwin, MO 63011 

Rev. 1—11/12/2009 

Содержание SPG

Страница 1: ...ut reading ALL of this manual and the safety precautions and warnings illustrated in this manual KDAR Company Tel 314 692 8555 15009 Manchester Road 283 Fax 314 692 8578 Ballwin MO 63011 Web Site www hotmaxtorches com Operator s Manual Model SPG Spool Gun Spool Gun ...

Страница 2: ...er helmet or shield when operating ANSI Z49 1 approved shade 9 rec ommended for all cutting currents less than 300 amperes The lens should conform to ANSI Z87 1 standards for testing Wear approved safety glasses with side shields under the face protection Warn others not to stare at the arc as it can cause damage to the eyes Provide barriers to protect other workers in the area from the arc while ...

Страница 3: ...inder Never cut any type of pressurized cylinder an explosion could result Always turn your face away from the valve when opening the cylinder Read and follow all instructions on compressed gas cylinders associated equipment and CGA pub lication P 1 listed in the Safety Standards before using ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current used in arc welding can create Electro Magn...

Страница 4: ...ia Health and Safety Code Section 25249 5 et seq PRINCIPAL SAFETY STANDARDS AMERICAN WELDING SOCIETY AWS C5 2 Recommended Practices for Plasma Arc Cutting AWS F4 1 Recommended Safe Practices for the Preparation for Welding and Cutting OSHA STANDARDS OSHA 29 CFR 1910 Safety and Health Standards NATIONAL FIRE PROTECTION ASSOCIATION NFPA Standard 70 National Electric Code NFPA Standard 51B Cutting an...

Страница 5: ...s Equipped With Pre Wired Spool Gun Switch Welds with Aluminum Stainless Steel Flux Core and Solid Steel Wire 2 Year Limited Warranty Table 1 Model SPG Spool Gun Welding Process Aluminum Flux Core Steel Stainless Steel Wire Sizes 030 or 035 8 or 9 mm Spool Size 4 Inch Diameter Duty Cycle at Rated Welding Current See Welder Specifications Weight 7 lbs Cable Length 20 0 Feet Cooling Method See Welde...

Страница 6: ...r panel or disconnect switch and discharge capaci tors before working inside the equipment Take care not to touch electrically hot parts Make sure the unit is switched off before plugging it into a the power outlet 1 Spool Gun and Lead Assembly 2 Spool Cover 3 1 Lb Spool 030 Aluminum Wire 4 Spool Tension Spring 5 Spool Tension Adjustment Nut 6 Shielding Nozzle 7 030 Contact Tip 8 Manual 1 2 3 4 5 ...

Страница 7: ...downs therefore dirt and dust around the unit should be kept to a minimum The WFG Welder should be placed on a stable level surface suitable to hold the unit s weight Components and Controls 1 Trigger Assembly 2 Spool Tension Knob 3 Spool Tension Spring 4 Shielding Gas Nozzle 5 Contact Tip 6 Wire Tension Adjustment Knob 7 Wire Drive Roll 8 Idle Roll 9 Lead Cable 10 Straight Gun Tube 11 Spool Cover...

Страница 8: ...et Up Gas 1 Set the welder for GMAW welding with positive electrode polarity connect the cable coming from the wing nut on the connector block to the positive output terminal and the ground lead to the negative output terminal Make sure all connec tions are tight See welder manual for gas connec tion instructions Welder Set Up Flux Core 1 Set the welder for FCAW welding with negative electrode pol...

Страница 9: ...s diffuser 11 Slide the contact tip over the wire and thread it into the gas diffuser 12 Slide the shielding gas nozzle over the wire and contact tip and thread it onto the gas dif fuser 13 Tighten the spool tension adjustment knob to increase the pressure of the drive wheel on the wire being fed 14 Reinstall the spool cover and cover retaining knob 15 Turn the welder on pull the trigger to insure...

Страница 10: ...minated shield ing gas 3 Confirm proper gas mixture is be ing used Change gas and check for improved appearance 4 Excessive air flow or windy envi ronment 4 Change welding location or shield the work area 5 Wrong electrode polarity 5 Wire for electrode positive No or low gas flow 1 Out of gas 1 Refill or replace tank 2 Gas supply is turned off 2 Turn on gas supply 3 Gas supply is disconnected 3 Co...

Страница 11: ...KDAR Company 10 Notes ...

Страница 12: ...RE TURN THIS WELDER TO THE RE TAILER Contact KDAR Company for in structions Visit www hotmaxtorches com or call KDAR Company M F 8AM 5PM CST to locate the nearest Authorized Service Center Not Covered 1 Transportation charges for sending or deliver ing the welder to the Authorized Service Cen ter or returning the repaired or replacement welder back to the customer These charges are the responsibil...

Отзывы: