background image

KDAR Company 

Item 

What To Do 

Each 

Use 

First 

Month or 
20 Hours 

Every 3 

Months or 

50 Hours 

Every 6 

Months or 
100 Hours 

Every  Year 

or 300 
Hours 

Engine Oil 

Check Oil Level 

  

  

  

  

  

Change 

  

  

  

Air Cleaner 

Check 

  

  

  

  

  

Clean or Replace 

  

  

  

  

Sedimant Cap 

Clean   

  

  

  

  

Spark Plug 

Check, adjust gap and clean 

  

  

  

  

Spark Arrester 

Clean 

  

  

  

  

Valve Clearance 

Check & Adjust 

  

  

  

  

Fuel Tank and Strainer 

Clean 

  

  

  

  

Fuel Filter (Attached to fuel 
valve) 

Clean - Replace if necessary 

  

  

  

  

Fuel Line 

Clean - Replace if necessary 

  

  

  

  

Exhaust System 

Check for leakage. Tighten 
or replace gasket, if neces-
sary 

  

  

  

  

Fittings & Fasteners 

Check, replace if necessary 

  

  

  

  

Maintenance Schedule—Engine 

Maintenance 

Engine Oil Change 

1.  Change oil while engine is warm to assure 

complete and rapid draining. 

2.  Power washer should be on a level surface. 
3.  Remove oil filler cap. 
4.  Place pan under generator to catch oil. 
5.  Remove oil drain plug. 
6.  Allow oil to drain completely. 
7.  Replace drain plug. 
8.  Refill with recommended oil (page 5). 
9.  Check oil level. 

Oil Filler 

Cap 

Oil Drain 

Plug 

Air Cleaner Service 

1.  Unsnap the air cleaner cover clips. 
2.  Remove the air filter element. 
3.  Wash the element in a solution of household 

detergent and warm water and rinse thoroughly 
(a nonflammable or high flash point solvent 
can also be used). 

4.  Allow to dry completely. 
5.  Pour a small amount of clean en-

gine oil on the element and 
squeeze out the excess. 

6.  Reinstall air filter element and 

replace cover.  

1.  Unsnap the air cleaner cover clips. 
2.  Remove the air filter element. 

Spark Arrestor Cleaning 

Note: Muffler must be cool to touch. 

1.  To remove the Spark Arrestor, loosen screw on 

clamp and remove the Arrestor. (Make sure to 
handle carefully and gently) 

2.  Lightly brush the element in a solution of 

household detergent and warm water and rinse 
thoroughly (a nonflammable or high flash 
point solvent can also be used). 

3.  Re-install Arrestor and tighten Clamp. 

Содержание Hot Max Torches PW3600

Страница 1: ...ot assemble install or operate this equipment without reading ALL of this manual and the safety precautions and warning illustrated in this manual KDAR Company 3671 New Town Blvd St Charles MO 63301 Tel 636 493 9920 Fax 636 493 9921 Web www hotmaxtorches com ...

Страница 2: ...ecific applications Do not modify or use for any application for which it is not designed 4 Do not tamper with the parts that may increase or decrease the gov erned engine speed Increased engine speed increases the chance of personal injury 5 Always remove the spark plug or spark plug cable before performing mainte nance to avoid accidental starting 6 Never operate a power washer with missing or b...

Страница 3: ... exhaust vapors can be trapped DANGER CARBON MONOXIDE HAZARD The engine exhaust contains carbon monoxide a poisonous odorless invisible gas which if breathed may cause death or personal injury KDAR Company 2 b Good ventilation for cooling The power washer is air cooled and requires appropriate air flow Temperatures should not exceed 104 F ambient c Refuel the power washer in a well ventilated area...

Страница 4: ...ne Pump Assembly 2 Operator s Manual 3 Warranty Card 4 Spark Plug Wrench 5 Screw Driver 6 Gun Handle 7 Extension Spray Wand 8 20 Hose 9 0 Spray Nozzle Red 10 15 Spray Nozzle Yellow 11 25 Spray Nozzle Green 12 40 Degree Spray Nozzle White 13 Detergent Nozzle Black 14 Tip Cleaner 15 Handle 16 Wheels w Axle Attached 2 17 Holder for Hose 18 Holder for Gun 19 Bolts M6x45 4 20 Bolts M6x40 2 21 Nuts M6 6...

Страница 5: ...e Manual Recoil Starter Handle Nozzle Gun Extension Spray Wand Throttle Thermal Relief Valve Water Supply Connection Thermal Relief Hose Detergent Take Up Hose Water Output Oil Cap High Pressure Hose Fuel Tank Extension Spray Wand Wheel Pump Muffler ...

Страница 6: ... 1 Use 4 stroke oil or an equivalent high deter gent premium quality motor oil certified to meet or exceed U S automobile manufactur er s requirements for Service Classification SG SF CC CD This designation will be on the motor oil container 2 SAE 10W 30 is recommended for general all temperature use See chart for appropriate weights for your area 3 Locate the oil filler cap and remove Oil Filler ...

Страница 7: ... are equipped with spark arresting mufflers allowing for use around agricul tural crops forests brush grass and other similar items Spark arresting mufflers are required in the State of California and on some U S Forest Ser vice Land and may also be legally required under other statutes and ordinances The California stat ues requiring a spark arresting muffler are Sections 13005 b 4442 and 4443 Pu...

Страница 8: ...e ON position 5 Pull starter rope with a fast steady pull Starter Rope Handle 6 As engine warms up return choke back to open position DANGER Provide adequate ventilation for toxic exhaust gases and cooling air flow Do not start or run the power wash er in and enclosed area even if win dows or doors are open Engines give off carbon monoxide a odorless colorless poison gas Breathing carbon monoxide ...

Страница 9: ...ay cleaner onto a dry surface For a vertical surface start at the bottom and move up using a horizontal motion 4 Allow solution to remain on the surface for a short time to work in 5 Rinse surface under high pressure from bottom up and then from top down CAUTION Only car wash detergents developed for use with a pressure washer and mild soaps should be used with this pressure washer Only chemi cals...

Страница 10: ...to catch oil 5 Remove oil drain plug 6 Allow oil to drain completely 7 Replace drain plug 8 Refill with recommended oil page 5 9 Check oil level Oil Filler Cap Oil Drain Plug Air Cleaner Service 1 Unsnap the air cleaner cover clips 2 Remove the air filter element 3 Wash the element in a solution of household detergent and warm water and rinse thoroughly a nonflammable or high flash point solvent c...

Страница 11: ... spark plug is to be reused 4 Measure the plug gap with a feeler gauge 5 Correct as necessary by carefully bending the side electrode The gap should be 0 70 0 80 0 028 0 031 in 8 Check to make sure the spark plug washer is in good condition 9 Thread the spark plug in by hand to prevent cross threading 10 After the spark plug is seated tighten with the spark plug wrench to compress the washer If in...

Страница 12: ...ted inside the water supply connection 1 Carefully remove the screen 2 Thoroughly wash the screen 3 Carefully replace the screen Take care not to damage the screen in any way the pump may be damaged if foreign matter gets into the pump If the screen is damaged DOT USE THE POWER WASHER WITH A DAMAGED SCREEN OR NO SCREEN Or der a new screen and replace before using Preparing for Transportation 1 Tur...

Страница 13: ...ngine oil Drain Carburetor 1 Loosen the carburetor drain screw 2 Drain carburetor into a suitable container 3 Replace drain screw WARNING Gasoline is extremely flammable and is explosive under certain conditions Do not smoke or allow flames or sparks in the area when the carbure tor is being drained Be careful not to spill fuel when draining the carburetor Spilled fuel or fuel vapor may ignite Avo...

Страница 14: ... cap 3 Set the plug side electrode on the cylinder head 4 Crank engine sparks should jump across the gap WARNING Be sure there is no spilled fuel in the area Gasoline is extremely flamma ble and is explosive under cer tain conditions Is the fuel reaching the carburetor YES Clean the fuel sediment cup and fuel filter NO To Check 1 Turn off the engine switch and loosen the carburetor drain screw 2 F...

Страница 15: ...ly including hose gun and wand If pressure is still not restored take the power washer to a authorized KDAR ser vice center YES YES YES YES YES YES NO NO NO NO NO NO No Intake of Chemicals Is injection tube securely attached to unit Is the injection tube cracked or split Is the correct nozzle attached to the wand Is the injection tube strainer clogged or blocked If injection is still not restored ...

Страница 16: ...er washer to the nearest KDAR Authorized Service Center for evaluation Visit www hotmaxtorches com or call KDAR Company M F 8AM 5PM CST to locate the nearest Authorized Service Center Not Covered 1 Transportation charges for sending or deliver ing the power washer to the Authorized Ser vice Center or returning the repaired or re placement power washer back to the customer These charges are the res...

Отзывы: