3 USE 

 
To ensure correct use of the equipment, follow the instructions below: 
 

 

Make sure the transmitter you are going to use is the correct one, identifying the 
hoist/crane on the identification label. 

 

 

Attach the strap to the transmitter unit. Its use is recommended to prevent the 
equipment from falling. 

 

 

Install a charged battery, turn the key-switch and activate the transmitter.  

 

 

To activate the system, you must first pull out the STOP button, the transmitter LED 
should then give a yellow-green pulse; then press the START button. If you find that 
the STOP button has already been pulled out, it is necessary to push it in and then pull 
it out again, as this sequence will allow the checking of the STOP circuit. If the unit 
has experienced a time-out auto-disconnection, it is not necessary to repeat the STOP 
button procedure, simply push the START button for 1 second. 

 

 

The transmitter LED should light up in green, indicating that the transmitter has started 
transmitting. From now on, if any of the transmitter’s command buttons are pressed, 
the corresponding motion will be activated. 

 

 

To be able to start up the transmitter, all the command pushbuttons must be in the 
neutral position (not activated). This is not the case for the Hoist Selection functions. 

 

 

When 4 minutes have passed and no active motion command have been activated, the 
transmitter automatically switch OFF. To start it up once more, press the START 
button. 

 

 

The transmitter is equipped with a circuit for monitoring the battery level. When this 
level drops below a pre-established limit, the transmitter LED starts to flash in red; 5 
minutes later the transmitter switches OFF, and the crane’s main contactor is 
deactivated. During this time, the load has to be located in a safe position. 

 

 

The LCD display of the RAD-TF transmitter also shows the battery level of charge: 
Three dots for charge bigger than 50%, two dots when 50% or less, one dot when 10% 
or less, none when 5% or less. 

 

 

To switch OFF the transmitter, press the STOP button or turn OFF the key -switch 

 

Remember that you are going to control remotely a moving piece of machinery. 
The safety instructions described in chapter 3 of this manual must be strictly 
adhered to. 

RADS11 and RADF13 Users Manual ver1.2.doc 
KCI Hoists Corp.  reserves the right to modify this information without prior notification. 

Page 14 of 20 

 

 

Содержание BC60K

Страница 1: ...USER S MANUAL RADS11 RADF13 RADIO REMOTE CONTROL SYSTEMS 0341 RADS11 and RADF13 Users Manual ver1 2 doc KCI Hoists Corp reserves the right to modify this information without prior notification Page 1...

Страница 2: ...essages originated in the receiver 17 6 MAINTENANCE 18 6 1 Precautions 18 6 2 Preventive maintenance 18 6 3 Locating Break downs 19 7 Drilling pattern sheet 20 INDEX OF FIGURES Figure 1 Battery charge...

Страница 3: ...4 EN 61000 4 2 1995 EN 61000 4 3 1996 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 61000 4 11 1994 EN 61000 3 2 1995 EN 50178 1998 EN 60204 32 1998 EN 60529 1991 PrEN 13557 1999 PrEN 12077...

Страница 4: ...928MHz Baud rate 7200 bps Channel separation 12 5 KHz 25 KHz Channel Occupation 7 2 KHz Modulation FM GMSK Response Time 100 ms Temperature range 20 C to 65 C 4F to 150F The RAD TS and RAD TF transmi...

Страница 5: ...n Ensure that all site and prevailing safety regulations are followed Make sure that this manual is permanently available to the operator and maintenance personnel Keep the transmitter out of reach of...

Страница 6: ...een LED on top of each battery Each LED should light up indicating that recharging is in process Complete recharging takes approximately 12 hours After charging process is finished the green LED is tu...

Страница 7: ...rom any intense radioelectric disturbance sources and install the receiver using the 4 elastic rubber absorbers M8 supplied with the set 6 7 inch 10 inch Figure 2 Receiver Box dimensions The receiver...

Страница 8: ...according EN50178 containing a functional earth connection A in Europe green yellow ground cable is not recommended for this earth connection The power supply and relays must be protected against cur...

Страница 9: ...t the ground cable Use only the approved cables Select the appropriate voltage on the receiver 230 115 or 48 Vac RADS11 and RADF13 Users Manual ver1 2 doc KCI Hoists Corp reserves the right to modify...

Страница 10: ...t the ground cable Use only the approved cables Select the appropriate voltage on the receiver 230 115 or 48 Vac RADS11 and RADF13 Users Manual ver1 2 doc KCI Hoists Corp reserves the right to modify...

Страница 11: ...absence of defects on the board SIGNAL OFF if all radio channels in the band are free Flashing ON if the receiver is finding channels with RF signals DATA OFF if none of the radio channels contains si...

Страница 12: ...ON indicate that it is receiving a RF signal at the working frequency DATA Flashing ON each time a good frame is received without caring about ID This means that the data received has a correct forma...

Страница 13: ...if all the motions and the STOP button are functioning correctly 2 4 Spurious Disturbance The receiver has designed to become blocked if there is intense spurious disturbance arising from galvanic ind...

Страница 14: ...will be activated To be able to start up the transmitter all the command pushbuttons must be in the neutral position not activated This is not the case for the Hoist Selection functions When 4 minutes...

Страница 15: ...edback in the display is fast enough The movements of the crane in this mode of operation are inhibited this is there are no movement orders being sent by the transmitter or acknowledged by the receiv...

Страница 16: ...ey board for Hoist Condition Monitoring Unit 4 4 Switching from Tared Load to Actual Load The actual load is shown in the display unit as the Tared Load but an A is shown below the t in the bottom rig...

Страница 17: ...nitoring Unit These are EXITING SERVICE MODE This message is originated when the Hoist Condition Monitoring Unit is in Service mode within the menus and the transmitter is in Normal mode of operation...

Страница 18: ...ecks can show certain defects which can later be the cause of subsequent break downs and which can be readily rectified We recommend the following checks to be made from time to time Transmitter Check...

Страница 19: ...related to the remote control equipment and the installation must be checked If any of the relays is not activated the problem is associated with the remote control equipment LED COLOUR ON FLASHING ON...

Страница 20: ...ing pattern sheet 255 5 169 5 NO SCALE 255 5mm 10 169 5mm 6 7 RADS11 and RADF13 Users Manual ver1 2 doc KCI Hoists Corp reserves the right to modify this information without prior notification Page 20...

Отзывы: