background image

71.500 - Multi corer - Manual 

Lift up the unit and secure the snap hook at “D”, 

while pressing the unit upwards tighten the screw 

“E”. Don’t use any tools, as the unit 

must glide 

over the bar during release of the sampler. 

 

 

 

 

It is very important to attach the snap hook at 

“F”. Attaching at “G” will cause malfunction to 

the lid. 

 

 

 

The handle behind the lid will secure the steel 
wire from top of sampler to the bottom release 
system.  
 
Press down the handle, ensure the wire is taut 
and release the handle. 
 

 

 

 

 

Содержание 71.500

Страница 1: ...KC Multi corer 4 x 100 mm Model 71 500 Manual KC Denmark Research Equipment Limnology Oceanography Hydrobiology...

Страница 2: ...6 9 11 Attaching the sample tubes 6 7 12 Lead weights 8 13 16 Adjustable penetration depth 8 9 17 Extending the corers footprint 9 18 The hydraulic damper 10 19 20 Deploying the multi corer 10 21 23 S...

Страница 3: ...must be released only when the multi corer is outside the rail of the boat Except for item 5 water filling of hydraulic damper KC Denmark A S is not and cannot be held responsible for any damage s ma...

Страница 4: ...mes with only one safety clamp Attach the safety clamp at the top of the corer ensuring the handle is locked properly at 1 The photo shows an old model with 2 safety clamps 2 Push up the lid The wire...

Страница 5: ...ools as the unit must glide over the bar during release of the sampler 4 It is very important to attach the snap hook at F Attaching at G will cause malfunction to the lid 5 The handle behind the lid...

Страница 6: ...l wire is inserted into J so the bottom lid is locked in open position When loaded you must avoid an unattended release as the mechanism may cause injury to people 7 Open the quick release bracket for...

Страница 7: ...reinforcement at the top 10 The reinforcement of the tube is aligned at the quick release Check if the lower end of the tube is inserted correct item 8 11 Tighten the handle to secure the tube Do not...

Страница 8: ...weights Adjustable penetration depth 13 Before mounting the bracket for adjustable penetration depth optional you must ensure that the security clamp is placed correctly see item 1 14 The bracket is a...

Страница 9: ...tration move the bracket in vertical position and fasten by means of the 4 bolts 16 Extending the corers footprint 17 Four extension legs optional can be added for better stability in strong currents...

Страница 10: ...or deployment When the rack is outside the bulwarks you can remove the safety clamps 1 The photo shows an old model with 2 safety clamps If you must remove the security clamp while the sampler is on d...

Страница 11: ...ejecting the sample 22 For emptying the sample tube you must hold a thin plate at the end of the tube to keep the sample while removing the tube 23 The sample ejection aggregate is optional 1 The sam...

Страница 12: ...ts must be rinsed carefully with fresh water to avoid rust and corrosion You can store the sampler in two ways 1 In loaded position having both safety clamps attached 2 You may remove the safety clamp...

Страница 13: ...to the weight station at the top of the rack When you raise the sampler it is important to have a reasonable weight on the rack to ensure the closing mechanism will work correctly If the weight of th...

Отзывы:

Похожие инструкции для 71.500