background image

13.030 

 Kajak Sediment Sampler 

 Ver. 2.15 - Manual 

9

 

Safety Regulations 

 

KC Denmark A/S is not, and cannot be held, responsible for any damage(s) made to equipment or to 
operators who ignore safety precautions or because of misuse or wrong operation.  

 

An expert maintenance technician fully familiar with the attendant hazards must only do all maintenance, 
inspection and repairs.  
 
When working with the unit in areas, which are difficult to access or hazardous, ensure to take adequate 
safety precautions for the operator and others in compliance with the provisions of law on health and 
safety at work.  
 
Replace worn component with original spare parts.  

 

 

Rev.: May 24, 2022 - lkj 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

KC

 

Denmark A/S

 

Research Equipment 

Limnology 

 Oceanography 

 Hydrobiology 

 

E-mail

[email protected]

 website

http://www.kc-denmark.dk/

 

Holmbladsvej 17-19, DK 8600 Silkeborg, Denmark. Tel. +45 86 82 83 47 

Bank: Sydbank. SWIFT: SYBKDK22 - IBAN DK5070460000104832  

VAT no. DK 29 61 96 62 

 

Содержание 13.030

Страница 1: ...Kajak Sediment Sampler Model 13 030 Manual KC Denmark A S Research Equipment Limnology Oceanography Hydrobiology...

Страница 2: ...The sampler can also be equipped with AISI 316 stainless steel corer tubes The upper part of the sampler can be exchanged with a shaft to sample by manual insertion of the tube The shafts are made of...

Страница 3: ...them using these dimensions Upper O ring 55 x 5 mm Lower O ring 59 5 x 3 mm 2 Place the upper part of the corer horizontally and insert the sample tube in the upper part Press the corer tube firmly in...

Страница 4: ...fore you ease the Kajak corer over the rail press the movable part in which the blue rubber bung is mounted upwards until the 2 lock arms slide into the notch of the bar The Kajak Corer is now ready f...

Страница 5: ...n finished you can seal it for later research by inserting rubber bungs at each end of the tube IMPORTANT Smear the rubber bung with a thin layer of silicone grease before use Ejecting the sample 10 A...

Страница 6: ...d for cutting a small thin sample of a few mm Mounting the adapter for 80 mm sample tubes 12 Adapter 13 050 optional for 80 mm tubes The adaptor for 80 mm tubes is mounted in the Kajak like the tubes...

Страница 7: ...rs The spring C has been loaded and you must secure it by fingers to avoid losing it 15 Push down the spring mount the shaft and secure the nuts A B Attach a polyester line or similar to the hook C Be...

Страница 8: ...in the stainless steel top Otherwise it is very difficult to separate the parts as the bung might expand a little All parts of the item can be rinsed using salt water or fresh water Before storing we...

Страница 9: ...epairs When working with the unit in areas which are difficult to access or hazardous ensure to take adequate safety precautions for the operator and others in compliance with the provisions of law on...

Отзывы:

Похожие инструкции для 13.030