Страница 1: ...297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Carlton Suite Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 418782 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com Wireless Ethernet Point to Point Multipoint Systems Operations Manual Version 20111027 ...

Страница 2: ...odule WAP WAPOM or subscriber unit WSU WSUP WSUDI WSUOM Qty 1 PIM Qty 1 PS 500 A Qty 1 LNBMB excluded in WAPOM or WSUOM Qty 1 Strain Relief for Ethernet cable connection at RJ 45 LAN port of WES module Qty 1 Operations manual P 1 Wireless Ethernet PtP MP System Operations Manual PREFACE CONTINUED TECHNICAL SUPPORT AVAILABILITY This manual is comprehensive to the extent that it will answer many of ...

Страница 3: ...ANT SAFETY INSTRUCTION For your protection please read and observe all safety instructions before operating this system and keep this sheet and any additional instructions for future reference INSTALLATION USE OBSERVE WARNINGS All warnings in the operating instructions should be carefully followed Do not make any modifications to the Wireless Ethernet Module WEM Power Injection Module PIM or any o...

Страница 4: ...it not expressly approved by the party responsible for compliance could void the users authority to operate the equipment Changes or modifications not expressly approved by KBC could void the users authority to operate the equipment iii Wireless Ethernet PtP MP System Operations Manual FCC POWER OUTPUT RESTRICTIONS The FCC does not require licensing to implement this device License free operation ...

Страница 5: ...otherwise noted The channels of each set of Host Clients must be matched for the radios to communicate with each other For multi connect devices each Client must be set to the same channel as the Host that it will be connected to If connecting more than one Client to a single Host please see the advanced operation section of this manual for multipoint setup 2 Mount the Client at the remote locatio...

Страница 6: ...y of IP cameras DVR NVRs managed non managed switches encoders decoders and web servers to be used across long range wireless line of sight links A FRONT VIEW 1 Module case 2 Antenna cover B REAR VIEW 1 Serial Number 2 List of Available Frequencies 3 Channel Selector on side of WEM Factory set to channel 0 unless otherwise noted 4 Status LEDs Amber Link Activity Red Power Green Signal Level 5 LAN ...

Страница 7: ...LED responses determined by the type of product in use POINT TO POINT HOST LED ACTIVITY WES 2500 WES 2 4 Hosts If the green LED flashes at any rate it is indicating a less than max signal connection MULTIPOINT HOST LED ACTIVITY WAP WAPOM CLIENT LED ACTIVITY All Clients from all part numbers excluding WAP WAPOM The Client LED status will remain the same regardless of the type of host to which it is...

Страница 8: ...diagram to the left 3 Power cycle device to implement channel change 4 Reseal port by replacing weatherproof plug B MOUNT DIRECTIONAL HOST CLIENT Mount the Host Client using the included wall pole mount bracket and hardware Connect the black mounting assembly with adjustment swivel to mounting L shaped bracket with the 20 button head screw Connect the unit to the mounting assembly using the mounti...

Страница 9: ...ending on the physical and RF environment a useable throughput rate may not be possible Contact KBC for more information 888 366 4276 or info kbcnetworks com 8 Wireless Ethernet PtP MP System Operations Manual ADVANCED OPERATION WEB BROWSER INTERFACE Each Host and Client has a web browser interface to access the advanced setup functions If changing advanced settings be sure to connect and power th...

Страница 10: ..._____ Subnet Mask The filter used for association of Ethernet devices _________ WIRELESS MAC Address The MAC address of the radio Record this information for tracking purpose __________________________________ Current Trans Rate The Client will display its signal rate to the Host Max is 54 _ Current Frequency Client Current frequency scanned for AP________________ Turbo Mode Available on 5765 5805...

Страница 11: ...ped or collided packets As the system continues to run these numbers will accumulate until cleared to 0 Refresh to see updated statistics ETHERNET STATISTICS Packet information at the motherboard and cable level If packets are dropped or collided at the Ethernet level then there could be a problem with the cabling or other LAN related hardware WIRELESS STATISTICS Packet information across the wire...

Страница 12: ...EL SWITCH OVERRIDE A drop down list of frequencies will appear Make sure that if changing frequencies using a connected wireless link the channel on the opposite end is configured first For units with the 25 5 dBi jumper ON selecting 5280 5300 or 5320 will default to 5745 as only 5745 5825 is available 2 Wireless Security Mode The WES can be configured to various forms of wireless encryption and c...

Страница 13: ...vice name for the Host and or Client ADMIN PASSWORD To change the password type in the desired password change and confirm Record all password changes as there are no ways to reset to default later if the password is lost or forgotten ADMINISTRATION The device name can be changed here Each unit does not have to have a matching device name in order to associate This name will appear on the status i...

Страница 14: ...itch Super Mode Disabled Encryption Cipher WPA 2 AES Device Name WES SP Host WES MP Host WES Client depends on software type 18 Wireless Ethernet PtP MP System Operations Manual ADVANCED OPERATION CONTINUED H ADVANCED FIRMWARE This page is used to flash firmware updates when necessary FIRMWARE INFORMATION Current firmware is 7 06 for all units using channel selector switches that have 8 positions ...

Страница 15: ...ni WAPOM WSUOM 2 5 dBi 5 8 GHz Small patch WES 2500 WAP WSU 7 8 dBi 5 8 GHz Large patch WES 2 4 WSUP 16 7 dBi 5 8 GHz Small patch in 18 inch parabolic dish 24 dBi 5 8 GHz Beam Width Omni 360 Small Patch 90 Large Patch 24 Dish 8 Data Throughput Rate Up to 20 Mbps Standard Mode Up to 50 Mbps Super Mode FCC ID JRRWES IC 4887A WES MANAGEMENT Interface 10 100 Base T half full duplex rate auto negotiate...

Страница 16: ... WEMs are aimed properly You should have clear wide open line of sight between the WEM modules Try a different frequency and cycle power Verify sufficient voltage into each PIM If MP Host the green LED should flash see page 5 Problem Suggestion All three solid LEDs but no video Check video at the camera Check wiring into encoders or decoders Try a different frequency and cycle power Connect one WE...

Страница 17: ...n implied warranty lasts so the above exclusions or limitations may not apply to you f If you do not wish to be bound by any of the provisions in this warranty please return the product s immediately 3 Contact your dealer regarding return authorizations for out of warranty repairs and any further product information 24 Wireless Ethernet PtP MP System Operations Manual APPENDIX The appendix section...

Страница 18: ... Address Remote Location 2 Head End Location in Single Point to Point Application Device S N Host Client IP Address Radio MAC Address Remote Location 3 Device S N Host Client IP Address Radio MAC Address Remote Location 4 Device S N Host Client IP Address Radio MAC Address Head End Location Device S N Host Client IP Address Radio MAC Address A 2 ...