6.2

 

 Class A ITE 

This  is  a  Class  A  product.  In  a  domestic  environment  this  product  may  cause  radio 
interference in which case the user may be required to take adequate measures. 
 

6.3

 

 FCC 

This equipment has been tested and found to comply with the limits for a Class A digital 
device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial  environment.  This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instruction 
manual,  may  cause  harmful  Interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at this own expense. 

 

 

7

 

Instruction of Disassembly          

Instruction of Disassembly of KBC Product 

(For EU Directive 2002/95/EEC-WEEE) 

 

Tools required: 

 

No. 1 Phillips screwdriver 

 

No. 2 Phillips screwdriver 

 
Steps for disassembly: 
 

1.

 

Remove tightening screws of box cover (8 screws). 

2.

 

Remove cover plate. 

3.

 

Remove tightening screws for printed circuit board (PCB). 

4.

 

Take out all PCBs. 

 

Notice: When a product reaches the end of its life – return to KBC. 
 

 

Содержание ESUG4P-PG2

Страница 1: ...Ethernet Switch User Manual ESUG4P PG2 ...

Страница 2: ...5 2 1 PACKAGE CONTENTS 5 2 2 CONFIGURATIONS 5 2 2 1 Physical Connections 6 2 3 INSTALLATION METHOD 7 2 3 1 DIN Rail Mount 7 2 3 2 Wall mount 7 2 4 ETHERNET RJ45 CONNECTIONS 7 2 5 SFP PORTS 8 2 6 POWER CONNECTIONS 8 2 7 FAULT ALARM CONTACT 9 2 8 LED STATUS 10 3 TROUBLESHOOTING 11 3 1 SELF TESTING 11 4 SYSTEM EXAMPLE 12 5 DIMENSIONS 12 6 WARRANTY 13 6 1 WARRANTY INFORMATION 13 6 2 CLASS A ITE 14 6 3...

Страница 3: ...he units have redundant power supply terminals and an alarm output All copper ports are automatically configured and the plug and play design provides ease and speed of installation 1 1 1 ESUG4P PG2 The ESUG4P PG2 provides connectivity for up to four 10 100 1000 RJ45 twisted pair copper ports which are capable of simultaneously supplying IEEE802 3at PoE and two gigabit SFP ports Each of the four 1...

Страница 4: ...ation Standard IEEE 802 3 Transmission distance 100m PoE Physical port 4 x shielded RJ45 Standard IEEE 802 3at Power supplied per port 30W 55Vdc Electromagnetic compatibility Interference EN55022 Class A Immunity IEC61000 6 2 Power Input voltage 50 57Vdc Power consumption 5 5W no PoE 125 5W full load PoE Power supply Supplied separately Environmental Operating temperature 40 C 74 C 40 F 165 F Stor...

Страница 5: ...th DIN rail mount 2 x Wall mount brackets with screws Pluggable terminal block Quick Start Guide Note A 50 57Vdc PSU is required but supplied separately Please contact you dealer or distributor if a part is missing or damaged 2 2 Configurations Products are available in either DIN rail or wall mount packages with the following configurations Product Type DIN Rail Wall mount ESUG4P PG2 ...

Страница 6: ...Ethernet Switch User Manual Manual ESUG4P PG2_Series_HW Rev1201 Copyright KBC Networks Ltd Page 6 of 15 www kbcnetworks com 2 2 1 Physical Connections Top View ...

Страница 7: ...witch using the screws that have just been removed from the DIN rail mounting plate with a Phillips No 1 or No 2 screwdriver Position the unit on the required flat surface and secure with screws via the mounting plate holes Screws are not provided Attach copper cables as required Insert the male power block attached to the supplied in line PSU to the female power socket on the device and tighten t...

Страница 8: ... LX BX ZX in any permutation 2 6 Power Connections A 6 pin power terminal block should be used to connect the power cable to the unit V V 2 3 4 5 6 1 V V Figure 2 1 Power connections Contact number Connections 1 PWR2 2 PWR2 3 Fault alarm contact 4 Fault alarm contact 5 PWR1 6 PWR1 Note If only using one power source connect pin 1 to pin 5 and pin 2 to pin 6 otherwise the Power Fault Alarm will be ...

Страница 9: ... Page 9 of 15 www kbcnetworks com 2 7 Fault Alarm Contact The fault alarm contacts are in the middle of the 6 pin screw block terminal on pins 3 4 An open circuit will occur if a power failure is detected Fig 2 2 Fault Alarm Contacts 2 3 4 5 6 1 Load External power 24Vdc 1A resistance P Fail ...

Страница 10: ...ered device OFF There is no powered device attached or the power to the device has failed P5 P6 ON SFP port link established FLASH Active data flow OFF No connection to the network Ethernet RJ45 Ports P1 to P4 Status LED Each RJ45 Ethernet port has two green indicators an upper and lower The upper one indicates the state of the port link and the lower one indicates port link speed Lower LED ON Por...

Страница 11: ...pective inputs or not If problems are encountered when using this Ethernet switch please check the following Verify that the correct power supply unit is being used this unit requires a 48Vdc supply Ensure that the correct cables are being used to construct your network o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections o 100Ω Cat 3 cable or above for 10Mbps connections o 100Ω...

Страница 12: ...thernet Switch User Manual Manual ESUG4P PG2_Series_HW Rev1201 Copyright KBC Networks Ltd Page 12 of 15 www kbcnetworks com 4 System Example Figure 4 1 ESUG4P PG2 Typical System Application 5 Dimensions ...

Страница 13: ...al shock exposure to moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY c FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES 1 THE COST OF...

Страница 14: ...nment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful Interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense 7 Instruction of Dis...

Страница 15: ...630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com data delivered ...

Отзывы: