data delivered 

Содержание EE1R3

Страница 1: ...Extended Ethernet 100 Series Chassis User Manual EE1R3 ...

Страница 2: ...3 3 1 2 TECHNICAL SPECIFICATION 3 2 INSTALLATION 4 2 1 PACKAGE CONTENTS 4 2 2 CONFIGURATIONS 4 2 2 1 Physical Connections 4 2 3 INSTALLATION METHOD 5 2 3 1 Chassis 5 2 4 POWER CONNECTIONS 5 2 5 LED STATUS 6 3 TROUBLESHOOTING 7 4 SYSTEM INSTALLATION EXAMPLE 7 5 DIMENSIONS 8 6 WARRANTY 9 6 1 WARRANTY INFORMATION 9 6 2 CLASS A ITE 10 6 3 FCC 10 6 4 UL 10 7 INSTRUCTION OF DISASSEMBLY 11 ...

Страница 3: ...en media converters which are hot swappable The chassis is provided with an integral 100 240Vac 3 3A power supply and an AC power cord A fan provides air flow for system cooling and there are LED indicators for power and fan status 1 2 Technical Specification Connectors Converter Slots 15 Electromagnetic compatibility Interference FCC Part 15 Class A CE Power Power Input 100 240Vac 3 3A Power Cons...

Страница 4: ...rter chassis with integral power supply unit Mounting brackets for 19 enclosure Rubber feet AC power cord Manual Note Extended Ethernet EE1CL units are sold separately Please contact you dealer or distributor if a part is missing or damaged within 10 days of receiving products 2 2 Configurations 2 2 1 Physical Connections Chassis front view P1 P2 FA FB Chassis rear view ...

Страница 5: ...assis Locate the converter chassis with the 19 mounting rails and attach using the screws provided With the power switch in the OFF position connect the power cord and then select the ON position for the power switch Insert the EE1CL units into the EE1R3 chassis as required Connect required media cables to the EE1CL devices See section 3 5 for LED status 2 4 Power Connections This unit must be pow...

Страница 6: ... of 12 www kbcnetworks com 2 5 LED Status LED Status Description Power PWR ON Power is supplied to the chassis OFF No power to the chassis FAN FAN A ON The fan is functioning correctly OFF The fan is not powered or there is a fault with the fan Note PWR2 and FAN B LEDs are not used on this product ...

Страница 7: ...o indicate the presence of power If the green light does not come on check that the power switch is in the ON position With power to the chassis the green fan light should be lit to show that the fan is functioning correctly If the fan LED remains off when the power is on there is a fault with the Fan please contact KBC Networks 4 System Installation Example Figure 4 1 EE1R3 Typical System Install...

Страница 8: ... Ethernet User Manual Manual EE1R3_Series Rev1208A Copyright KBC Networks Ltd 2012 Page 8 of 12 www kbcnetworks com 5 Dimensions 440mm 88 5mm Chassis front view Chassis depth 140mm Chassis rear view P1 P2 FA FB ...

Страница 9: ...moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY c FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES 1 THE COST OF LABOR TO REPAIR OR R...

Страница 10: ...ated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should b...

Страница 11: ...ruction of Disassembly of KBC Product For EU Directive 2002 95 EEC WEEE Tools required No 1 Phillips screwdriver No 2 Phillips screwdriver Steps for disassembly 1 Remove screws to cover plate 2 Remove cover plate 3 Remove mounting screws for printed circuit board PCB 4 Take out all PCBs Notice When a product reaches the end of its life return to KBC Networks ...