background image

 

 

Page 8 of 8 

3)

 

Use a network cable to connect the RJ45 port of the transmitter and the 
powered  device.  Plug  the  network  cable  into  the  UTP  port  of  the 
transmitter and use a grounding wire to connect the grounding terminal.  

 

4)

 

Check that the installation is correct and power on the device to be sure 
it is operating normally. 

 

Troubleshooting 

Please refer to the following information if the device does not work: 

 

Confirm the installation has been done according to the factory 
installation requirements. 

 

Confirm the RJ45 cable order is in accordance with the EIA/TIA568A or 
568B industry standards. 

 

The maximum transmission distance depends on the signal source and 
cable quality. Please do not exceed the maximum transmission distance. 

 

Try replacing each end with a known working unit to determine if you 
have a damaged or faulty unit. 

 

If the problem persists, please contact your nearest KBC office or dealer. 

 

Need Help? 

Please visit our website 

www.kbcnetworks.com

 or contact your nearest KBC 

office or dealer.

 

Содержание eCopper EERF1-LS1-T-MN-B

Страница 1: ...ty The plug and play design ensures ease of installation with no electrical adjustment needed LED indicators are provided to show the operational status of the unit The size of the transmitter is suited for fitting inside camera housings and where space is minimal Features 802 3af 802 3at compliant Power over Wire technology UTP data rate 40Mbps 300m Based on cable quality cable pairs used 1 2 or ...

Страница 2: ...age which may have been caused during shipping Physical Deployment This equipment must be installed and operated in accordance with instructions found in this document Failure to comply with these instructions will invalidate the warranty Application Panel views Top view ...

Страница 3: ...or 4 Ethernet RJ45 port 5 Grounding terminal LED Color Status Description PWR Orange On Power supply is normal PoW Green On PoW power supply is normal U LINK Green On EoU connection is normal PoE Green On Successful handshake with PD and supplying power to PD E L A Orange On Blink On Ethernet link is normal Blink Data is active ...

Страница 4: ... 3 PoW 4 PoW 5 PoW 6 PoW 7 PoW 8 PoW Notes Please use straight through cable rather than cross over cable 8 wires transmission all 8 wires need to be connected 4 wires transmission any 2 wires of PIN 1 2 4 and 5 as any 2 wires of PIN 3 6 7 and 8 as 2 wires transmission any 1 wire of PIN 1 2 4 and 5 as any 1 wire of PIN 3 6 7 and 8 as ...

Страница 5: ...Page 5 of 8 Dimensions Unit mm Equipment Installation Accessories ...

Страница 6: ...rent protection time 2mS Transmission distance 400m Ethernet Port Transmission medium Cat5e 6 Standard IEEE802 3 IEEE802 3U Ethernet delay 1mS Protection ESD IEC61000 4 2 Anti thunder protection IEC61000 4 5 level 3 Operation Environment Operating temperature 20 70 Storage temperature 40 85 Humidity Non Condensing 0 90 Mechanical Dimension L W H 76mm 37mm 29mm Material Aluminum Color Black Weight ...

Страница 7: ...efore installation If any items are missing please contact the dealer EoU transmitter x1 Wall mounting clamp x1 QSG User manual x1 Screws x2 Please follow the installation steps below 1 Attach the clamp to the wall using the 3X10mm screws 2 Press the receiver into the clamp ...

Страница 8: ...not work Confirm the installation has been done according to the factory installation requirements Confirm the RJ45 cable order is in accordance with the EIA TIA568A or 568B industry standards The maximum transmission distance depends on the signal source and cable quality Please do not exceed the maximum transmission distance Try replacing each end with a known working unit to determine if you ha...

Отзывы: