4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
ASSEMBLY INSTRUCTIONS
CONNECT ELECTRICAL WIRING
INSTALL GRILLE
3
Install ceiling material to complete the ceiling construction.
Then, cut around the fan housing.
To attach the grille assembly to the fan housing, Insert the light plug from the
grille assembly into the wire panel. Pinch the grille springs on the sides of the
grille assembly, and position the grille into the housing with the grille springs
in the appropriate slots. Push the grille assembly towards the ceiling to secure.
UNIT
BLACK (BLK)
NIGHT
LIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
RED
WHITE (WHT)
BLUE (BLU)
FAN
RECEPTACLE
LIGHT
RECEPTACLE
WIRE
PANEL
The ducting from this fan to the outside of building has a strong effect on
the air flow, noise and energy use of the fan. Use the shortest, straightest
duct routing possible for best performance, and avoid installing the fan with
smaller ducts than recommended. Insulation around the ducts can reduce
energy loss and inhibit mold growth. Fans installed with existing
ducts may not achieve their rated air flow.