Kaz HWM705 series Скачать руководство пользователя страница 4

END-OF-SEASON CARE AND STORAGE

When the humidifier will not be used for at least one week, or it is the end of the season, fol-

low the 

WEEKLY CARE AND CLEANING

 instructions in this manual.

If it is the end of the season, remove and discard any accessories from the humidifier. 
Dry the humidifier completely before storing. 

Do not 

store with water inside the Base, Heating 

Chamber or Water Tank.
Pack unit in original carton and store in a cool, dry location.

REASSEMBLE HUMIDIFIER

1.

Place Removable Tray over heating element. Push Locking Tab toward back of unit so Removable

Tray Lift Tab locks in place.

2.

Align Cooling Chamber Tab over Removable Tray. Push Locking Tab toward back of unit so

Cooling Chamber Tab locks into place beside Removable Tray Tab.

3.

Replace Water Tank on Base.

4.

Humidifier is ready to use. See Operating Instructions.

WEEKLY CARE AND CLEANING 

(Continued from previous page)

TROUBLESHOOTING

Solution

•  Plug unit in
•  Check circuits, fuses, test outlet

•  Fill Water Tank
•  Place on a level surface
•  Follow Cleaning Instructions

on previous pages

•  Rinse thoroughly with

clean water

•  Refill Water Tank
•  Follow Reset Procedure

•  Check Water Tank for leaks; contact

Consumer Relations if necessary

•  Tighten Tank Cap

•  Decrease mist output to low

setting and/or open door to

the room

If your Humidifier is not working properly, refer to the following:

Problem

•  Power Knob is set to “On”

and green light around 

Power Knob is off

•  Little or no mist is produced

•  Reset Light illuminated

•   Water  overflows

from Reservoir

•  Condensation forms around

humidifier or on windows

Possible Cause

•  Unit not plugged in
•  No power at outlet

•  No water in Water Tank
•  Unit is not level
•  Mineral deposits on Heating

Element or Removable Tray

•  Water Tank was washed

with detergent

•  Water Tank is empty
•  Unit not reset after refill

•  Water Tank may be leaking

• Tank Cap is not tight

•  Mist intensity is set too

high for room size or

pre-existing humidity level

NOTE:

 Failure to keep this unit clean from mineral deposits normally contained in any water 

supply will affect the efficiency of operation of this unit. Customer failure to follow these 
instructions may void the warranty.

Instructions for Scale Removal (continued)

5.

Fill Heating Chamber with 1 cup undiluted white vinegar. Vinegar should completely cover

Heating Element. 
Place Removable Tray over Heating Element. Push Locking Tab towards back of the unit so 

Removable Tray Tab locks in place.
Vinegar solution will loosen mineral buildup (scale) on Heating Element and bottom of Cooling 

Chamber as they soak.

6.

Soak Heating Element in vinegar solution for 15-20 minutes then gently scrub with a soft

brush to remove mineral deposits. 

Do not

 use hard brushes, steel wool or other hard abrasives 

on the heating element. Doing so will damage the heating element.
Rinse Base and Removable Tray with water until smell of vinegar is gone.

 

CAUTION: Do not

 immerse base in water. 

7.

Wipe Cooling Chamber, Medicine Cup and Removable Tray with a little vinegar and clean cloth

if not already cleaned in dishwasher.

 Step 7

 Step 6

 Step 5

Instructions for Disinfecting

Follow Steps 1-4 in Scale Removal Instructions in previous section.

For Step 5: While humidifier is disassembled, add 1 tsp of bleach to 1 gallon (3.8L) of water 

and fill Water Tank with this solution. Replace Tank Cap. Swish solution around in Water Tank. 
If not cleaning Removable Tray, Mist Chimney and Medicine Cup in dishwasher, use some of 

the bleach solution to wipe these components clean. 
Empty tank and rinse all components with water until smell of bleach is gone.

NOTE: 

Using more than 1 tsp of bleach per gallon (3.8L) of water may result in damage to 

your humidifier. 
See steps 6-7 in Scale Removal Instructions in previous section to complete Disinfecting process.

NOTE:

 

Do not 

mix vinegar and bleach solutions together. Scale Removal and Disinfecting must 

be done separately.

 Step 5

Содержание HWM705 series

Страница 1: ...contact a qualified electrician Do not attempt to defeat this safety feature 5 To avoid fire or shock hazard plug the appliance directly into a 120V AC electrical outlet 6 The appliance should always be unplugged and emptied when not in operation or while being cleaned Shut off and unplug humidifier before moving Do not move or tilt humidifier while it is in operation Plug and unplug unit with dry...

Страница 2: ...U S or Vicks VapoSteam VS177CANEA in Canada Can be added to medicine cup area to provide soothing menthol vapors to help provide comfort Protec Cleaning Cartridge PC 1BXN in U S or PC 1C in Canada Keeps your humidifier cleaner longer Continuously cleans and protects humidifiers against bacteria and mold for 30 days 1 Remove humidifier and all contents from box Save Use and Care Manual for future u...

Страница 3: ...e humidifier turned off unplugged and cooled for at least 20 30 min gently wipe residue from Medicine Cup 3 Do not add liquid inhalants or any additives other than those recommended by the manufacturer and do not add liquid inhalants or any additives directly to the water Doing so can have adverse effects on the humidifier Step 2 Step 1 Liquid Inhalant Step 3 To properly clean your humidifier we r...

Страница 4: ...Cap is not tight Mist intensity is set too high for room size or pre existing humidity level NOTE Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit Customer failure to follow these instructions may void the warranty Instructions for Scale Removal continued 5 Fill Heating Chamber with 1 cup undiluted whi...

Отзывы: