CONTENTS PAGE

PRECAUTIONS ........................................................................... 1
ACCESSORY .............................................................................. 1
INSTALLATION ........................................................................... 2
WIRING ....................................................................................... 6
SPECIFICATION PARAMETER ................................................ 10
KRE APPLICATION. .................................................................. 11
MAINTENANCE AND UPKEEP ................................................ 11
TRAIL RUN. ............................................................................... 11
ERP INFORMATION. ................................................................ 12

1. PRECAUTIONS

To prevent injury to the user or other people and property 

damage, the following instructions must be followed. Incorrect 

operation due to ignoring of instructions may cause harm or 

damage. The appliance should be installed by a professional in 

accordance with the specified instructions.

The safety precautions listed here are divided into two categories. In 

either case, important safety informations are listed which must be 

read carefully.

WARNING

Failure to observe a warning may cause electric shock, 

fire hazard or personal injury

CAUTION

Failure to observe a caution may cause injury or damage 

to the equipment.

WARNING

● Ask your dealer or qualified personnel to carry out installation 

work. Do not try to install the machine by. Incorrect installation 

may result in leakage, electric shocks or fire.

● Installation should be done by following the installation manual 

and no changes should be made to the unit. Incorrect installation 

may cause leakage, electric shock, or fire. If the KRE falls, it may 

cause damage and injury.

● Install the unit on a foundation that is strong enough to withstand 

the weight of the unit. 

A foundation of insufficient strength may result in the equipment 

falling and causing injuries.

● Do not allow exhaust air to enter the outside air inlet. 

This may cause the air of the room to become contaminated, 

harming the health.

● Locate the outside air intake vent so that it does not take in 

exhaust air which contains combustion air, etc. 

Incorrect installation may cause a loss of oxygen in the room, 

leading to serious accidents.

● Make sure that a separate power supply circuit is provided for 

this unit and that all electrical work is carried out by qualified 

personnel according to local laws and regulations and this instal-

lation manual. 

Insufficient power capacity, improper electrical works, or incorrect 

wiring may cause electric shock or fire.

● Make sure Earth Leakage Breaker is the type of all poles drop-out.

● Be sure to ground. 

Do not connect the ground wire to gas or water pipes, lightning rod 

or a telephone ground wire. 

Incomplete grounding may result in electric shocks.

● Make sure that all wiring is secured, the specified wires are used, 

and no external forces act on the terminal connections or wires. 

Improper connections or installation may result in overheating or 

fore.

● When wiring the power supply and connecting the remote control-

ler wiring and transmission wiring, position the wires so that the 

electric parts box lid can be securely fastened. 

Improper positioning of the electric parts box lid may result in 

electric shocks, fire or the terminals overheating.

CAUTION

● Be sure to install an earth leakage breaker. 

Failure to install an earth leakage breaker may result in electric 

shocks.

● Install the indoor and outdoor units, power supply wiring and 

connecting wires at least 1 meter away from television or radio 

in order to prevent image interference or noise. (Depending on 

the radio waves, a distance of 1 meter may not be sufficient 

enough to eliminate the noise.)

● Install the two outdoor ducts with down slope to prevent rainwa-

ter from entering the unit. 

If this is not done completely, water may enter the building, may 

damage furniture, etc.

● Insulate the duct and the wall electrically when a metal duct is to 

be penetrated through the metal lattice and wire lattice or metal 

lining of a wooden structure wall. 

Improper duct work may cause electric shocks or short circuits.

● Make sure that a snow protection measure is taken. If no pro-

tection snow may enter through the outdoor ducts, and cause 

damaging furniture and electric shock and fire.

2. ACCESSORY

Table 2-1

Name

Qty.

Shape

Purpose

Installation and 

owner’s manual

1

This manual must be delivered to the 

customer

Notes: Wired controller should be purchased separately.

Prepare the following on site.

Table 2-2

Name

Purpose

PVC drain pipe

For connecting unit’s drain pipe, which length is 

selected according to your actual requirement 

(Only required for Model 1500 and 2000 

Damper

For vibration damping, when lift the unit.

Содержание KRE-500D1

Страница 1: ...hasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL KRE Heat Recovery Ventilation KRE 500D1 KRE...

Страница 2: ...hysical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards i...

Страница 3: ...t heat exchange core Air filter Sheet metal type air duct Air filter By pass Return air inlet Supply air outlet Electric control box Return air inlet Fan Supply air outlet Sheet metal type air duct Ai...

Страница 4: ......

Страница 5: ...s or incorrect wiring may cause electric shock or fire Make sure Earth Leakage Breaker is the type of all poles drop out Be sure to ground Do not connect the ground wire to gas or water pipes lightnin...

Страница 6: ...cal government office or fire department for details When discharging exhaust air to a common duct the Building Standard Law requires the use of fire proof materials so attach a 2m copper plate standi...

Страница 7: ...ly and without sustain the weight form condensate water pipe and air duct The vents of air inlet outlet and return should be connected with flexible tube Unit in AC 220 240V 50Hz reliable grounding ea...

Страница 8: ...5 1 1 KRE 500D1 KRE 1000D1 Fig 3 5 Door Electric control box Exhaust air outlet Return air inlet Supply air outlet Fresh air inlet By pass system Table 3 1 Unit mm Model L L1 L2 W1 W2 W H H1 N N1 KRE...

Страница 9: ...Door Door Return air inlet Flange dimension Flange dimension Supply air outlet Electric control box Exhaust air outlet Fresh air inlet Electric control box By pass system Exhaust air outlet Fresh air...

Страница 10: ...ircular wiring terminal with insulation Use power cord that conforms to the specifications and connect the power cord firmly To prevent the cord from being pulled out by external force make sure it is...

Страница 11: ...ommunication wiring between the KRE and outdoor units should be connected one unit after another in a daisy chain from the out door unit to the final KRE unit And the shielded layer must be properly g...

Страница 12: ...E D2 E Y E E D1 X X R P Q X E D2 E Y E E D1 T X R P Q X E D2 E Y E E Fig 4 4 Indoor unit 1 Wired controller 1 Master wired controller Wired controller 1 Wired controller 2 Master wired controller Sla...

Страница 13: ...properly installed otherwise electric shocks or a fire may result Dispose of this unit properly and in accordance with regulations If electrical appliances are disposed of in landfills or dumps hazard...

Страница 14: ...60 1000 KRE 1500D1 1830 1520 770 346 326 181 5 180 1500 KRE 2000D1 1900 1720 845 346 326 208 5 200 2000 Table 5 2 Model Nominal temp efficiency Nominal enthalpy efficiency Sound power level dB Power i...

Страница 15: ...ontroller owner s manual installation manual Attached in the package box in wire controller 7 MAINTENANCE AND UPKEEP 7 1 During early use one should check the fan operation regu larly 7 2 The cleaning...

Страница 16: ...at optimum energy efficiency 0 1517 kw 10 2 Rated motor flow rate s at optimum energy efficiency 0 1614m3 s 10 3 Rated motor pressure s at optimum energy efficiency 270 Pa 11 Rotations per minute R P...

Страница 17: ...nergy efficiency 0 276 kw 10 2 Rated motor flow rate s at optimum energy efficiency 0 34m3 s 10 3 Rated motor pressure s at optimum energy efficiency 360 Pa 11 Rotations per minute R P M at the optimu...

Страница 18: ...77 2 7 Nominal flow rate m3 s 0 139 0 278 0 417 0 556 8 Electric power input kW 0 157 0 383 0 677 0 956 9 SFPint W m3 h 682 785 702 730 10 Face velocity m s 0 66 0 87 1 0 1 0 11 Nominal external pres...

Страница 19: ...15 16126100000189 V4 0...

Страница 20: ......

Отзывы: