Page

0.  Safety Precautions ........................................................................................  4

1.  Indoor Unit Parts and Major Functions .......................................................  6

2.  Manual Operations .......................................................................................  8

3.  Care and Maintenance .................................................................................  9

a. 

Unit Maintenance

b. 

How to Clean the Air Filter

c. 

Repairing Refrigerant Leaks

d. 

Preparation for Periods of Non-use

4. Troubleshooting ............................................................................................ 11

a. 

Common Problems

b. 

Troubleshooting Tips

c. 

Error Codes

5.  European Disposal Guidelines ..................................................................... 15

Caution: Risk of fire /

flammable materials

WARNING: 

Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance 

and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the 
person competent in the use of flammable refriferants. For more details, please refer to the Information on 
Servicing on INSTALLATION MANUAL (This is only required for the unit adopts R-32 Refrigerant).

Содержание KPD-35 DVN12

Страница 1: ...to save this manual for future reference OWNER S MANUAL Duct A6 Type KPD 35 DVN12 KPD 52 DVN12 KPD 71 DVN11 KPD 90 DVN12 KPD 105 DVN11 KPD 105 DTN11 KPD 140 DVN11 KPD 140 DTN11 KPD 160 DTN11 KPD 35 D...

Страница 2: ...140 DVN11 KPD 140 DR11 KUE 140 DVN10 9 9 KPD 140 DTN11 KPD 140 DR11 KUE 140 DTN10 9 9 KPD 160 DTN11 KPD 160 DR11 KUE 160 DTN10 9 9 KPD 35 DVR12 KPD 35 DR12 KUE 35 DVR12 9 9 KPD 52 DVR12 KPD 52 DR12 KU...

Страница 3: ...g Tips c Error Codes 5 European Disposal Guidelines 15 Caution Risk of fire flammable materials WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and r...

Страница 4: ...rate the defrosting process to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an...

Страница 5: ...riods of usage check the indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroug...

Страница 6: ...used under different conditions it may malfucntion or become less efficient FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER When outside temperature is below 0 C 32 F we strongly recommend keeping t...

Страница 7: ...losed to keep cool or warm air in the room DO NOT place objects near the air inlet and outlet of the unit This will reduce the efficiency of the unit Set a timer and use the built in SLEEP ECONOMY mod...

Страница 8: ...ntrol has been misplaced or is out of batteries Fig 2 1 MANUAL button This button selects the mode in the following order AUTO FORCED COOL OFF FORCED COOL mode In FORCED COOL mode the Operation light...

Страница 9: ...ot wash the unit under running water Doing so creates an electrical hazard Do not use water hotter than 40 C 104 F to clean the front panel This can cause the panel to become deformed or discolored Cl...

Страница 10: ...event of a refrigerant leak the LCD screen will display EC and the LED indicator light will flash Preparation For Periods Of Non Use Maintenance after Extended Non Use 1 Remove any obstacles blocking...

Страница 11: ...he unit changes from COOL mode to FAN mode The unit changes its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature...

Страница 12: ...h will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odour The unit may absorb odours from the environment suc...

Страница 13: ...s are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long term use Che...

Страница 14: ...Other twin model malfunction 10 OFF E9 10 Overload protection 1 ON F0 11 Outdoor temperature sensor error 2 ON F1 12 Outdoor condenser pipe sensor error 3 ON F2 13 Discharge air temperature sensor er...

Страница 15: ...buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers...

Страница 16: ......