Fig.1

 

 

 

 

 

air outlet

 

air inlet

 

Fix leg

 

Refrigerant piping 

connection part

 

(connection part in side)

 

 

 

NOTE

 

All the pictures in this manual are for explanation purpose only. They may be slightly different from the air 
conditioner you purchased (depend on model). The actual shape shall prevail.

 

 

16kW complying with IEC 61000-3-12.

 

Содержание KMF-80 DVN3

Страница 1: ...N3 KMF 120 DVN2 KMF 140 DVN2 KMF 160 DVN2 KMF 120 DTN2 KMF 140 DTN2 KMF 160 DTN2 KMF 180 DTN2 Original instructions Thank you very much for purchasing our air conditioner Before using your air conditi...

Страница 2: ...ing connection part connection part in side NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model...

Страница 3: ...s into the air inlet or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquerer paint near the unit It may cause a fire Never touch...

Страница 4: ...to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open fire in places exposed to the air flow from the...

Страница 5: ...let Blocks may decrease the efficiency of the unit or startup the protector which will stop running 4 2 About power cut If power is cut during operation stop all the operation immediately Power comes...

Страница 6: ...heat wind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and the...

Страница 7: ...Input current protection Compressor discharge protection temperature Condenser high temperature protection Inverter module protection Typhoon protection Indoor evaporator hi temp protection Module mal...

Страница 8: ...is because dust has gotten into the unit Symptom 6 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 7 The outdoor unit fan...

Страница 9: ...is blocked Outdoor unit and indoor unit heat exchanger are dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shines Too much h...

Страница 10: ...the MODE indicated on the display is FAN ONLY The temperature cannot be set during FAN mode The indication on the display disappears after a lapse of time Check whether the timer operation has come t...

Страница 11: ...MD14U 025BW 202000172622...

Страница 12: ......

Отзывы: