background image

owner’s manual

 

3

 

 

Adjust the air flow louver properly and avoid direct air flow to 
room inhabitants.

 

 

Adjust the room temperature properly for a comfortable 
environment. Avoid excessive heating or cooling.

 

 

Prevent direct sunlight during cooling operation by using 
curtains or blinds.

 

 

Ventilate often. Extended use requires special attention to 
ventilation.

 

Adjust vertical air

 

Open the horizontal air deflector, and then manually adjust 
vertical air deflector.

 

 

 

C faceplate

 

 

Keep  doors  and  windows  closed.  If  the  doors  and  windows 
remain open, air will flow out of your room causing a decrease 
in the cooling or heating effect.

 

 

Never place objects near the air inlet or the air outlet of the unit. 
It may cause deterioration in the effect or stop the operation.

 

 

Never place objects near the air inlet or the air outlet of the unit. 
It may cause deterioration in the effect or stop the operation.

 

 

Set the timer .

 

 

If you don't plan to use the unit for a long time, please take the 
batteries  from  the  remote  controller.  When  the  power  is  on, 
some energy will be consumed, even if the air conditioner isn't 
in operation. So please disconnect the power to save energy.

 

 

Keep  the  indoor  unit  and  remote  controller  at  least  1  m  away 
from  televisions,  radios,  stereos,  and  other  similar  equipment. 
Failing to do so may cause static or distorted pictures.

 

 

A dirty air filter will reduce cooling or heating efficiency, please 
clean it once two weeks.

 

 
 
 
 
 
 
 

S faceplate

 

 
 
 
 
 
 
 
 
 
 
 

 

6.  MAINTENANCE

 

 
 
 
 
 
 

Vertical air deflector

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Vertical air deflector

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig.5-2

 

 

5.  ADJUSTING AIR FLOW DIRECTION

 

 

While the unit is in operation, you can adjust the air flow louver 
to  change  the  flow  direction  and  naturalize  the  room 
temperature evenly. Thus, you can enjoy it more comfortably.

 

 

Adjust horizontal air

 

Adjust horizontal air deflector by remote controller.

 

 

C faceplate

 

CAUTION

 

 

Before you clean the air conditioner, be sure the power 
supply is off.

 

 

Check if the wiring is not broken off or disconnected.

 

 

Disconnect the power supply before cleaning and 
maintenance. Use dry cloth to clean the unit.

 

 

Use a dry cloth to wipe the indoor unit and remote 
controller.

 

 

A wet cloth may be used to clean the indoor unit if it is 
very dirty.

 

 

Never use a damp cloth on the remote controller.

 

 

Do not use a chemically-treted duster for wiping or leave 
such material on the unit for long.

 

it may damage or fade the surface of the unit.

 

 

 
 

S faceplate

 

 

Horizontal air deflector

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Horizontal air deflector

 

 
 
 
 

 

 
 
 
 
 
 

Fig.5-1

 

Do not use benzine, thinner, polishing powder, or similar 
solvents for cleaning.

 

These may cause the plastic surface to crack or deform.

 

 

 

Maintenance after a long stop period

 

(eg. at the beginning of the season)

 

 

Check and remove everything that might be blocking inlet 
and outlet vents of indoor units and outdoor units.

 

 

Clean air filters and casings of indoor units.

 

Refer to "Cleaning the air filter" for details on how to proceed 
and make sure to install cleaned air filters back in the same 
position.

 

 

 

Содержание KFC-AY-2T-250D3

Страница 1: ...2T 400D1 KFC AY 2T 600D1 KFC AY 2T 250D2 KFC AY 2T 400D2 KFC AY 2T 600D2 KFC AY 2T 250D3 KFC AY 2T 400D3 KFC AY 2T 600D3 Thank you very much for purchasing our air conditioner Before using your air c...

Страница 2: ...let Air outlet Infrared signal Temperature receiver display Operation lamp Timer indicator Display panel S E T T E M P E R A T U R E C A U T O C O O L D R Y H E A T F A N H I G H M E D L O W T E M P F...

Страница 3: ...for special treatment is necessary To prevent water leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the water if by any chanc...

Страница 4: ...onditioner will run under AUTO mode The remote controller operation is enabled to operate according to the received signal 2 FORCED COOL The OPERATION lamp flashes the air conditioner will turn to AUT...

Страница 5: ...duce cooling or heating efficiency please clean it once two weeks S faceplate 6 MAINTENANCE Vertical air deflector Vertical air deflector Fig 5 2 5 ADJUSTINGAIRFLOWDIRECTION While the unit is in opera...

Страница 6: ...air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner Refer to Fig 6...

Страница 7: ...DC motor malfunction E3 T2 evaporator sensor malfunction E2 T1 evaporator sensor malfunction E8 Water level alarm malfunction E7 EEPROM communication error 8 TROUBLESHOOTING 8 1 Troubles and causes o...

Страница 8: ...ng FAN mode The indication on the display Check whether the timer The air conditioner operation will disappears after a lapse of operation has come to an stop up to the set time time end when the TIME...

Страница 9: ...MDV08U 012CW 202000171075...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: