4.  

Troubleshooting

CAUTION

If one of the following conditions occurs, switch off the power supply immediately and contact your dealer for further 
assistance.

•  The operation light continues to flash rapidly after the unit has been restarted.
•  The remote-control buttons do not work.
•  The unit continually trips fuses or circuit breakers.
•  A foreign object or water enters the air conditioner.
•  Other abnormal situations

Common Issues

The following problems are not a malfunction and, in most situations, will not require repairs.

Issue

Possible Causes

Unit does not turn on 
when pressing ON/OFF 
button

The unit has a 3-minute protection feature that prevents the unit from overloading. The 
unit cannot be restarted within three minutes of being turned off

Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/Defrost) 
indicators are lit up, the outdoor temperature is too cold and the unit's anti-cold wind is 
activated in order to defrost the unit.

In Cooling-only Models: If the "Fan Only" indicator is lit up, the outdoor temperature is too 
cold and the unit's anti-freeze protection is activated in order to defrost the unit.

The unit changes from 
COOL mode to FAN 
mode

The unit changes its setting to prevent frost from forming on the unit. Once the temperature 
increases, the unit will start operating again.

The set temperature has been reached, at which point the unit turns off the compressor. 
The unit will continue operating when the temperature fluctuates again.

The indoor unit emits 
white mist

In humid regions, a large temperature difference between the room's air and the 
conditioned air can cause white mist.

Both the indoor and 
outdoor units emit 
white mist

When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to 
moisture generated from the defrosting process.

The indoor unit makes 
noises

A squeaking sound is heard when the system is OFF or in COOL mode. The noise is also 
heard when the drain pump (optional) is in operation.

A squeaking sound may occur after running the unit in HEAT mode due to expansion and 
contraction of the unit's plastic parts.

Both the indoor unit 
and outdoor unit make 
noises

A low hissing sound may occur during operation. Thia ia normal and is caused by refrigerant 
gas flowing through both indoor and outdoor units.

A low hissing sound may be heard when the system starts, has just stopped running or is 
defrosting. This noise is normal and is caused by the refrigerant gas stopping or changing 
direction.

Содержание KCIS-105 DR11

Страница 1: ...AS and manufacturer information from the Owner s Manual Product Fiche in the packaging of the outdoor unit European Union Products only If used as MULTI unit please refer to the Installation Operation Manuals packed with outdoor unit OWNER S MANUAL Superslim Four Way Cassette Series KCIS 71 DR11 KCIS 90 DR12 KCIS 105 DR11 KCIS 105 DR11 KCIS 140 DR11 KCIS 125 DR12 KCIS 140 DTR11 KCIS 160 DTR11 ...

Страница 2: ......

Страница 3: ...ng Tips c Error Codes 5 European Disposal Guidelines 16 Caution Risk of fire flammable materials WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants For more details please refer to the ...

Страница 4: ...rate the defrosting process to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater The appliance shall be stored to prevent mechanical damage from occurring Be aware that the refrigerants may not contain an odor 0 Safety Preca...

Страница 5: ...heating devices thoroughly ventilate the room to avoid oxygen deficiency Do not climb onto or place objects on top of the outdoor unit Do not operate the air conditioner when using fumigant insecticides The chemicals may become layered with the unit and endanger those who are hypersensitive to chemicals Do not let children play with the air conditioner Do not operate the air conditioner in a wet r...

Страница 6: ... C 32 F 122 F 15 C 50 C 5 F 122 F For models with low temp cooling systems 18 C 54 C For special tropical models 7ºC 24ºC 0 C 60 C For special tropical models Fixed speed Type COOL Mode HEAT Mode DRY Mode Indoor Temperature 17 C 32 C 62 F 90 F 0 C 30 C 32 F 86 F 17 C 32 C 62 F 90 F Outdoor Temperature 18 C 43 C 64 F 109 F 7 C 24 C 19 F 75 F 18ºC 43ºC 64ºF 109ºF 7 C 43 C 19 F 109 F low temperature ...

Страница 7: ...closed to keep cool or warm air in the room DO NOT place objects near the air inlet and outlet of the unit This will reduce the efficiency of the unit Set a timer and use the built in SLEEP ECONOMY mode if applicable If you don t plan to use the unit for a long time remove the batteries from the remote control Clean the air filter every two weeks A dirty filter can reduce cooling or heating effici...

Страница 8: ...y panel on the indoor unit can be used to operate the unit in case the remote control has been misplaced or is out of batteries MANUAL button This button selects the mode in the following order AUTO FORCED COOL OFF FORCED COOL mode In FORCED COOL mode the Operation light flashes The system will then turn to AUTO after it has cooled with a high wind speed for 30 minutes The remote control will be d...

Страница 9: ...m Do not wash the unit under running water Doing so creates an electrical hazard Do not use water hotter than 40ºC 104ºF to clean the front panel This can cause the panel to become deformed or discolored Clean the unit using a damp lint free cloth and neutral detergent Dry the unit with a dry lint free cloth How To Clean The Air Filter The filter prevents dust and other particles from entering the...

Страница 10: ...h and safety threat Refrigerant Leak Detection System some models In the event of a refrigerant leak the LCD screen will display EC and the LED indicator light will flash Preparation For Periods Of Non Use Maintenance after Extended Non Use 1 Remove any obstacles blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of the indoor unit Reinstall the cle...

Страница 11: ...The unit changes from COOL mode to FAN mode The unit changes its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature has been reached at which point the unit turns off the compressor The unit will continue operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large tem...

Страница 12: ...ch will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odour The unit may absorb odours from the environment such as furniture cooking cigarettes etc which will be emitted during operations The unit s filters have become moldy and should be cleaned The fan of the outdoor unit does not operate During operation ...

Страница 13: ...and windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant The unit starts and stops frequently There s too much or too little refrigerant in the system Check for leaks and recharge the syste...

Страница 14: ... 10 OFF E9 10 Overload protection 1 ON F0 11 Outdoor temperature sensor error 2 ON F1 12 Outdoor condenser pipe sensor error 3 ON F2 13 Discharge air temperature sensor error 4 ON F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 ON F4 15 Outdoor fan speed DC fan motor only malfunction 6 ON F5 16 Auto lifting panel communication error 8 ON F7 17 Auto lifting panel ma...

Страница 15: ... flash 6 Outdoor malfunction Quick flash Quick flash E6 7 EEPROM malfunction Quick flash Quick flash E7 8 Water level alarm malfunction E8 Quick flash 9 DC motor speed out of control Quick flash Eb Quick flash 10 Outdoor unit low pressure malfunction Quick flash Quick flash Ed Quick flash 11 Auto lifting panel communication error Quick flash F0 Quick flash Quick flash 12 Auto lifting panel malfunc...

Страница 16: ...en disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers NOTE Disposing of this appliance in the forest...

Страница 17: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details QSQ4 001U D 16122700000121 20171108 ...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: