Troubleshooting Tips

When troubles occur, please check the following points before contacting a repair company.

Problem

Possible Causes

Solution

The unit is not 
working

Power failure

Wait for the power to be restored

The power switch is off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are dead

Replace the remote control batteries

The unit's 3-minute protection has been 
activated

Wait three minutes after restarting the unit

Poor Cooling 
Performance

Temperature setting may be higher than 
ambient room temperature

Lower the temperature setting

The heat exchanger on the indoor or outdoor 
unit is dirty

Clean the affected heat exchanger

The air filter is dirty

Remove the filter and clean it according to 
instructions

The air inlet or outlet of either unit is blocked

Turn the unit off, remove the obstruction and turn 
it back on

Doors and windows are open

Make sure that all doors and windows are closed 
while operating the unit

Excessive heat is generated

Close windows and curtains during periods of 
high heat or bright sunshine

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off 
refrigerant

The unit starts and 
stops frequently

There's too much or too little refrigerant in 
the system

Check for leaks and recharge the system with 
refrigerant

There is air, incompressible gas or foreign 
material in the refrigeration system

Evacuate and recharge the system with refrigerant

System circuit is blocked

Determine which circuit is blocked and re-place 
the malfunctioning piece of equipment

The compressor is broken

Replace the compressor

The voltage is too high or too low

Install a manostat to regulate the voltage

Poor heating 
performance

The outdoor temperature is lower than 7ºC 
(44.5ºF)

Check for leaks and recharge the system with 
refrigerant

Cold air is entering through doors and 
windows

Make sure that all doors and windows are closed 
during use

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off 
refrigerant

Содержание KAM2-42 DR7

Страница 1: ...ke sure to save this manual for future reference This manual only describes the outdoor unit of user s When using the indoor unit refer to the user s manual of indoor unit OWNER S MANUAL Outdoor Units R 32 KAM2 42 DR7 KAM2 52 DR7 1 KAM3 62 DR7 KAM3 78 DR7 1 KAM4 80 DR7 KAM4 105 DR7 KAM5 120 DR7 KAM5 120 DR8 ...

Страница 2: ......

Страница 3: ...e for R 32 Refrigerant only WARNING Servicing shall only be perfomed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants For more details please refer to the Information on servicing on INSTALLATION MANUAL This is only required ...

Страница 4: ...all be stored so as to prevent mechanical damage from occurring Be aware that the refrigerants may not contain an odour 0 Safety Precautions Compliance with national gas regulations shall be observed Keep ventilation openings clear of obstruction DO NOT pierce or burn A warning that the appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specifie...

Страница 5: ...the indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroughly ventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoor unit DO NOT operate the air conditioner when using fumigant insecticides The chemicals may become layered with the...

Страница 6: ...ying filter Air filter behind 5 Horizontal louver 6 LCD display window 7 Vertical louver 8 Manual control button behind 9 Remote controller holder Outdoor unit 10 Drain hose refrigerant connecting pipe 11 Connective cable 12 Stop valve 13 Fan hood Fig 2 2 Indoor unit 1 Air outlet 2 Air inlet 3 Air filter 4 Electric control cabinet 5 Wire controller Outdoor unit 6 Drain hose refrigerant connecting ...

Страница 7: ...ntaining air filter 3 Remote controller 4 Installation part 5 Display panel Outdoor unit 6 Drain hose refrigerant connecting pipe 7 Connective cable 8 Stop valve 9 Fan hood Fig 2 4 Indoor unit 1 Drain pump drain water from indoor unit 2 Drain hose 3 Air outlet 4 Air inlet 5 Air in grill 6 Display panel 7 Remote controllerr Outdoor unit 8 Refrigerant connecting pipe 9 Connective cable 10 Stop valve...

Страница 8: ...h resulting in lower heating efficiency in the air conditioner Under these conditions the air conditioner will stop heating operations and start defrosting automatically The time to defrost may vary from 4 to 10 minutes depending the outdoor temperature and the amount of frost buildup on the outdoor unit Auto Restart some models In case of power failure the system will immediately stop When power ...

Страница 9: ...ngly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature cannot be achieved with the air conditioner alone it is recommended that you use a supplementary heating device Lightning or a car wireless telephone operating neraby may cause the unit to malfunction Disconnect the unit from its power sou...

Страница 10: ...iodically Contact a local dealer of a customer service centre if the unit requires NOTE Before you clean the air conditioner be sure to switch off the unit and disconnevy the power supply plug Optimal operation To achieve optimal performance please note the following Adjust the direction of the air flow so that it is not blowing directly on people Adjust the temperature to achieve the highest poss...

Страница 11: ...ost the unit In Cooling only Models If the Fan Only indicator is lit up the outdoor temperature is too cold and the unit s anti freeze protection is activated in order to defrost the unit The unit changes from COOL mode to FAN mode The unit may change its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature has bee...

Страница 12: ...e different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odour The unit may absorb odours from the environment such as furniture cooking...

Страница 13: ...doors and windows are closed while operating the unit Excessive heat is generated Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant The unit starts and stops frequently There s too much or too little refrigerant in the system Check for leaks and recharge the system with...

Страница 14: ...n disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers NOTE Disposing of this appliance in the forest ...

Страница 15: ...change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version QSYTD 002U 16122300000198 20180716 ...

Страница 16: ......

Отзывы: