KAWNEER 1690 Скачать руководство пользователя страница 4

kawneer.com

Laws and building and safety codes gover

ning the design and use of glazed 

entrance, window

, and curtain wall pr

oducts vary widely

. Kawneer does not contr

ol 

the selection of pr

oduct configurations, operating har

dwar

e, or glazing materials, 

and assumes no r

esponsibility ther

efor

.

Kawneer r

eserves the right to change configuration without prior notice when deemed

necessary for pr

oduct impr

ovement.

© Kawneer Company

, Inc., 2008

4

11/16"

11/16"

31/32"

2-7/16"

3-1/8"

 

(PART NO. 038-283) 

EC 97904-8 

MAY, 2008

1690 TOUCHBAR CONCEALED EXIT DEVICE
INSTALLATION INSTRUCTIONS

Install the top strike in the normal position with the marker arrow toward door stop (see sketches below).
If adjustment is required the strike can be rotated either 90° or 180°. Shim strike to accommodate top door clearance

SINGLE DOOR

PAIR OF DOORS

OF PAIR OF DOORS

NOTE: Position strikes with
marker arrow toward door stop.

PLAN VIEW - TRANSOM / HEADER

TOP STRIKE
INSTALLATION

THRESHOLD
INSTALLATION

SINGLE DOOR

PAIR OF DOORS

PLAN VIEW - BUTT HUNG THRESHOLD (OFFSET PIVOT SIMILAR)

BOTTOM
LATCH BOLT

DOOR STOP

5/8" DIA.

HOLES

OF PAIR OF DOORS

DOOR STOP INSTALLATION

USING DOOR STOP AS A TEMPLATE, DRILL
(2) 5/32" (0.156) DIAMETER HOLES AND
SECURE STOP WITH SELF TAPPING SCREWS.

APPROXIMATELY 1/32"

WITH WEATHERING

WITHOUT WEATHERING

NOTE:
Dimensions are from centerline of housing mounting holes.

CRASH BAR TO TOUCHBAR RETROFIT

EXISTING HOUSING MOUNTING HOLE.
Existing holes will be exposed on pivot stile after retrofit.

**#17 DRILL THRU
   1/4-20 TAP (4) HOLES

EXISTING HOUSING
MOUNTING HOLE

**9/16" (0.562) DIA.

EXISTING HOUSING

MOUNTING HOLES

** THESE NEW HOLES MUST BE ADDED

SHIM

STRIKE

#8 THREAD CUTTING 

FASTENERS

Отзывы: