![KAWNEER 1690 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/kawneer/1690/1690_installation-instructions_3673961004.webp)
kawneer.com
Laws and building and safety codes gover
ning the design and use of glazed
entrance, window
, and curtain wall pr
oducts vary widely
. Kawneer does not contr
ol
the selection of pr
oduct configurations, operating har
dwar
e, or glazing materials,
and assumes no r
esponsibility ther
efor
.
Kawneer r
eserves the right to change configuration without prior notice when deemed
necessary for pr
oduct impr
ovement.
© Kawneer Company
, Inc., 2008
4
11/16"
11/16"
31/32"
2-7/16"
3-1/8"
(PART NO. 038-283)
EC 97904-8
MAY, 2008
1690 TOUCHBAR CONCEALED EXIT DEVICE
INSTALLATION INSTRUCTIONS
Install the top strike in the normal position with the marker arrow toward door stop (see sketches below).
If adjustment is required the strike can be rotated either 90° or 180°. Shim strike to accommodate top door clearance
SINGLE DOOR
PAIR OF DOORS
OF PAIR OF DOORS
NOTE: Position strikes with
marker arrow toward door stop.
PLAN VIEW - TRANSOM / HEADER
TOP STRIKE
INSTALLATION
THRESHOLD
INSTALLATION
SINGLE DOOR
PAIR OF DOORS
PLAN VIEW - BUTT HUNG THRESHOLD (OFFSET PIVOT SIMILAR)
BOTTOM
LATCH BOLT
DOOR STOP
5/8" DIA.
HOLES
OF PAIR OF DOORS
DOOR STOP INSTALLATION
USING DOOR STOP AS A TEMPLATE, DRILL
(2) 5/32" (0.156) DIAMETER HOLES AND
SECURE STOP WITH SELF TAPPING SCREWS.
APPROXIMATELY 1/32"
WITH WEATHERING
WITHOUT WEATHERING
NOTE:
Dimensions are from centerline of housing mounting holes.
CRASH BAR TO TOUCHBAR RETROFIT
EXISTING HOUSING MOUNTING HOLE.
Existing holes will be exposed on pivot stile after retrofit.
**#17 DRILL THRU
1/4-20 TAP (4) HOLES
EXISTING HOUSING
MOUNTING HOLE
**9/16" (0.562) DIA.
EXISTING HOUSING
MOUNTING HOLES
** THESE NEW HOLES MUST BE ADDED
SHIM
STRIKE
#8 THREAD CUTTING
FASTENERS