13.  Legend

Observe safety instructions

Manufacturer

Observe operating instructions

Protect from sunlight

Store in dry place

Protection against penetration of solid  

particles of ≥1.0 mm diameter and vertically 

falling water drops

Conformity mark according to

EU Council Directive 93/42/EEC

Direct current

Device of protection class II

Alternating current

Patient applied part of type BF

Do not dispose in domestic waste

On

Serial number

Off

Item number

Observe operating instructions

14.  Accessories and spare parts

Designation

REF

mamivac

®  

SENSITIVE-C breast pump (device)

281012

mamivac

®

 suction kit PREMIUM L

283120

mamivac

®

 double kit PREMIUM L 

283123

mamivac

®

 suction kit PREMIUM XL

283133

mamivac

®

 suction kit PREMIUM S

283129

Power unit for SENSITIVE-C

283008

Power unit for SENSITIVE-C UK

283008K01

Power unit for SENSITIVE-C US

283008K02

Power unit for SENSITIVE-C AU

283008K03

Operating instructions mamivac

® 

SENSITIVE-C

GB1010002M

mamivac

®

 suction kit ECONOMY L, small bottle

283122

mamivac

®

 double kit ECONOMY L, small bottle

283124

mamivac

®

 carrying case SENSITIVE-C

283011

mamivac

®

 carrying bag

 

 SENSITIVE-C

283010

mamivac

®

 Test unit

2899120

SN

REF

IP41

Содержание MAMIVAC SENSITIVE-C

Страница 1: ...rating instructions electric breast pump for rental Phone 49 0 71 56 1 76 02 100 Fax 49 0 71 56 1 76 02 500 info kaweco de KaWeCo GmbH Gerlinger Str 36 38 71254 Ditzingen Germany REF 284000 As of 2018...

Страница 2: ...7 3 3 The stimulation phase 17 3 4 The expressing phase 17 3 5 Switching off the device 18 4 Hygiene and cleaning 18 4 1 Cleaning and servicing the breast pump 18 4 2 Cleaning and servicing the mamiva...

Страница 3: ...aration of infant from mother metabolic disorders of the baby anatomic disorder in the face of the infant cleft lip jaw palate diseases of the mother where breastfeeding is temporarily contraindicated...

Страница 4: ...ly adjustable cycle control c Status LED flashing green ready for use yellow self testing red error message d Connection for power unit e Connection for suction kit f Connection for second suction kit...

Страница 5: ...cycles stimulate the flow of milk Turn on the pump by switching the vacuum control to Make sure that the vacuum control indicator is in the area marked green low vacuum Turn the cycle control to a hig...

Страница 6: ...ng vacuum in the breast shield to prevent damage to the tissue After cleaning rinse all parts thoroughly with lukewarm water to remove residues of the washing up liquid especially on those components...

Страница 7: ...pected WARNING Avoid using this device directly next to other devices or with other devices stapled on top of each other as this could disturb operation WARNING The use of accessories converters or ca...

Страница 8: ...screw it from the breast shield For further information regarding breast shield size please ask your lactation consultant or midwife Since expressing times strongly depend on the individual mother you...

Страница 9: ...be returned to the manufacturer 10 Environmental protection and disposal Please dispose of mamivac SENSITIVE C breast pumps in accordance with your local disposal regulations for electrical devices 11...

Страница 10: ...ructions 14 Accessories and spare parts Designation REF mamivac SENSITIVE C breast pump device 281012 mamivac suction kit PREMIUM L 283120 mamivac double kit PREMIUM L 283123 mamivac suction kit PREMI...

Отзывы: