Step 2
Measure the required length of the cage
and cut all 10 straps to the required length.
It is important to carefully remove any
sharp edges using a metal file.
Step 3
Line up all the straps on one end with the
bolt slot facing upwards and mark the
location of the intermediate hoop bolt
positions on all 10 straps.
Step 4
– Insert the intermediate hoop strap fixing
bolts into all 10 straps to the locations
marked.
– Then insert a strap fixing bolt to either
end of all straps for connection to the top
and bottom hoop.
11
INSTALLATION PROCEDURE
STEP 1 - PRE INSTALLATION CHECK
Prior to installation the condition of the fixed ladder
and structure to which it is attached must be
checked for suitability.
The cage entry height must be measured carefully
as it must be within 2.0 - 2.2 metres from the lower
landing (see diagram page 10).
The checklist on page 16 will assist with critical
assessment criteria.
Do not proceed with installation of this
system if any of the checking criteria does not
meet the required standards. Seek advice from
the manufacturer regarding other options.
STEP 2
Assemble top, lower and intermediate cage hoops using 1 M8 x 25
cup head bolt and nut set for each hoop.
Ensure dome head is placed on the inside of the cage to
avoid any injuries to users.
STEP 3
Measure the required length of the cage and cut all 10 straps to the
required length. It is important to carefully remove any sharp edges
using a metal file.
Ensure cage length allows for 2.0-2.2M space between lower
landing and cage and a minumum of 1000mm extension
above the roof landing (see diagram page 10).
Sayfa Systems
1029 Mountain Highway
Boronia Vic 3155
Tel:- 03 8727 9000
Fax:- 03 8727 9099
Email:- [email protected]
Web:- www.sayfa.com.au
1
REVISIONS
REMARKS
Date
2
3
4
5
SAYFA SYSTEMS CONFIDENTIAL MATERIAL
This drawing is copyright© and all rights are reserved.
The design and specifications contained herein are
confidential and the property of SAYFA SYSTEMS. The
information may not be divulged or used in any form or
by any means, for any purpose other than that stated by
SAYFA SYSTEMS. Storage or transmittal, copying or
reproduction, viewing or scanning of this Drawing by any
person or party, whether in whole or in part is prohibited,
except with express prior written consent by SAYFA
SYSTEMS.
Drawing No.
By Rep
14/5/2013
3563
MV
Update details
Replace Hoop
Drg update
Drg Update
...
XX
3/05/15
RP
3/05/15
2/7/15
MV
11/5/16
MV
Modular Ladder Cage with Adjustable
Extrusion
Aluminium
Material
Product
Code
FAB NO:
Note: All Drawings are designed to comply with AS 1657
2000
-2200
Cage
Lengt
h
=
Hei
ght
les
s1100m
m
Height?
MA
X 1
800
Sp
acin
g
Ensure Straps are cut to correct length.
Straps
M
ax
1500
2. Join The hoops together
M8 x 20 Cup Bolt
3. Slide the cup-bolt into strap
4. Attach Flanged Nut
1. Cut extrusion to desired length
(10 Straps required per cage)
Dr
awing No
. 356
3
Ensure cage length allows for 2.0-2.2m space
between lower landing and cage and a minimum
of 1000mm extension above the roof landing.
12
INSTALLATION PROCEDURE
STEP 4
Line up all the straps on one end with the bolt slot facing upwards
and mark the location of the intermediate hoop bolt positions on all
10 straps.
Depending on the length of the cage, the intermediate hoops
are to be equally spaced. Max spacing 1800mm.
STEP 5
Insert the intermediate hoop strap fixing bolts into all 10 straps to
the locations marked.
Then insert a strap fixing bolt to either end of all straps for
connection to the top and bottom hoop.
STEP 6
Attach number
2 strap
to top hoop first. Use battery operated
impact driver to secure firmly.
Ensure the strap rounded face is attached on the inside
of the cage hoop.
Nut
Outside Cage
Inside Cage
Domed Bolt
1
REVISIONS
REMARKS
Date
2
3
4
5
SAYFA SYSTEMS CONFIDENTIAL MATERIAL
This drawing is copyright© and all rights are reserved. The
design and specifications contained herein are confidential
and the property of SAYFA SYSTEMS. The information may
not be divulged or used in any form or by any means, for any
purpose other than that stated by SAYFA SYSTEMS. Storage,
transmittal, forwarding to third party, copying, reproduction,
viewing or scanning of this Drawing by any person or party,
whether in whole or in part is prohibited, except with express
prior written consent by SAYFA SYSTEMS. The perspective is
only an indication of the planned installation.
Drawing No.
Rep
By
Sayfa Group
1029 Mountain Highway
Boronia Vic 3155
Tel:- 03 8727 9000
Fax:- 03 8727 9002
Email:- [email protected]
Web:- www.sayfa.com.au
2/7/15
6057
...
...
...
...
Proofing
MV
Cage hoop and Strap numbers
Aluminium
Material
Product
Code
FAB NO:
1
2
3
4
5
6
7
8
9
10
Dr
awing No
. 605
7
12
INSTALLATION PROCEDURE
STEP 4
Line up all the straps on one end with the bolt slot facing upwards
and mark the location of the intermediate hoop bolt positions on all
10 straps.
Depending on the length of the cage, the intermediate hoops
are to be equally spaced. Max spacing 1800mm.
STEP 5
Insert the intermediate hoop strap fixing bolts into all 10 straps to
the locations marked.
Then insert a strap fixing bolt to either end of all straps for
connection to the top and bottom hoop.
STEP 6
Attach number
2 strap
to top hoop first. Use battery operated
impact driver to secure firmly.
Ensure the strap rounded face is attached on the inside
of the cage hoop.
Nut
Outside Cage
Inside Cage
Domed Bolt
1
REVISIONS
REMARKS
Date
2
3
4
5
SAYFA SYSTEMS CONFIDENTIAL MATERIAL
This drawing is copyright© and all rights are reserved. The
design and specifications contained herein are confidential
and the property of SAYFA SYSTEMS. The information may
not be divulged or used in any form or by any means, for any
purpose other than that stated by SAYFA SYSTEMS. Storage,
transmittal, forwarding to third party, copying, reproduction,
viewing or scanning of this Drawing by any person or party,
whether in whole or in part is prohibited, except with express
prior written consent by SAYFA SYSTEMS. The perspective is
only an indication of the planned installation.
Drawing No.
Rep
By
Sayfa Group
1029 Mountain Highway
Boronia Vic 3155
Tel:- 03 8727 9000
Fax:- 03 8727 9002
Email:- [email protected]
Web:- www.sayfa.com.au
2/7/15
6057
...
...
...
...
Proofing
MV
Cage hoop and Strap numbers
Aluminium
Material
Product
Code
FAB NO:
1
2
3
4
5
6
7
8
9
10
Dr
awing No
. 605
7
13
Kattsafe / Modular ladder cage / Installation manual
Copyright, trademarks and product codes are property of Kattsafe.