MAINTENANCE
IC120-2 ENG
4-32
AIR INTAKE AND EXHAUST SYSTEM
Clean and Replace Air Cleaner Element
If the air cleaner clogging lamp on the instrument panel
is lit, the element is clogged.
Replace the element.
1. Disconnect the housing clip (2) of the pre-cleaner (1).
Detach the pre-cleaner from the housing (6).
2. Take out the pre-cleaner sub-assembly (3) and
primary element (4), and clean the inside of the
housing by wringing wet cloth and remove mud or
foreign substances.
3. Take out the secondary element (5) and clean the
surrounding area. Mount the secondary element
immediately so that foreign substances will not enter
the engine.
4. Push the primary element (4) into the housing so that
the O-ring will be located on the secondary element
side. Apply force to two tabs on the side to ensure
perfect accommodation.
5. Clean the inside of the pre-cleaner and pre-cleaner
assembly, and reassemble it to the original position.
6. Press the reset switch on the top of the dust indicator
(7) located in the rear of the housing.
• Be sure to stop the engine before cleaning or changing the air cleaner. If it is cleaned
or changed while the engine is running, dust is sucked in, causing engine damages.
• When removing the secondary element, be careful not to introduce particles and
foreign objects into the air cleaner pipe.
• Primary and secondary elements are disposable. You cannot reuse them by blowing
air to them and cleaning them.
Содержание IC120-2
Страница 1: ...IC120 2 CB004001 IC120 2 0988477EN 00 0988477EN 00...