background image

1 / 4

House connection ampli

fi

 ers for modern/new HFC networks 

up to 1000 MHz

Frequency-dependent gain due to integrated interstage 
equaliser (pre-emphasis 8 dB) 

Variable gain in forward path using slide switches 

Integrated diplexers

LED indicates operational mode

Die-cast housing with F-type connectors  

Delivery scope: VOS 22 (FR/RA), instructions for use

VOS

22/FR

20910024

VOS

22/RA

20910025

House connection ampli

fi

 ers

Features

VOS 22/FR

Integrated return path 5-65 MHz 

passive

 and can be 

switched off (switchable using bridging plugs, delivery status 
passive)

VOS 22/RA

Integrated return path 5-65 MHz 

active/passive

 and can be 

switched off (switchable with bridging plugs, delivery status 
passive)

The ampli

fi

 ers comply with the requirements in the EMC

Directive 2004/103/EC and Low-Voltage Directive 
2006/95/EC applicable at the time of shipping.

• The ampli

fi

 er supply voltage is 230 V and is a serious danger to life in the event of direct physical contact!

•  The only reliable method of disconnecting the ampli

fi

 ers from the mains is to unplug them.

•  Do not touch live parts.
•  The power plug must be easily operable as the means of cutting power to the ampli

fi

 er, meaning the wall outlet must be

close to the ampli

fi

 er and easily accessible.

•  The power must be cut when installing or removing the ampli

fi

 er.

• The ampli

fi

 ers must not be operated without the standard 

fi

 tted power supply unit guard cover. The cover must be 

closed.

• No liquid-

fi

 lled items may be placed on top of the ampli

fi

 ers.

• The ampli

fi

 ers must not be exposed to dripping or splashing water.

•  Permissible ambient temperature -20 to +55°C

Basic safety measures

•  Installation must be carried out by authorised specialist staff.
•  Unplug from the mains before installation.
• The ampli

fi

 ers described are exclusively for installation of HFC networks up to 1000 MHz.

•  Any other use or failure to comply with these instructions will result in voiding of warranty coverage.
• The ampli

fi

 ers may only be installed in dry indoor areas. Do not mount on or against highly combustible materials.

• The ampli

fi

 ers must be provided with an equipotential bonding wire (Cu, at least 4 mm

2

) .

•  The safety regulations set out in the current EN 60728-11 and EN 60065 standards must be complied with.

Содержание VOS 22/RA

Страница 1: ...rennvorrichtung des Verst rkers muss ohne Schwierigkeiten benutzbar sein d h die Netzsteck dose muss in der N he des Verst rkers angebracht und leicht zug nglich sein Die Installation und Deinstallati...

Страница 2: ...s 85 1000 MHz 3 dB 0 dB 6 dB Steckbr cken zur Einstellung des R ckwegs 5 65 MHz Beide Jumper m ssen auf die gleiche Position gesteckt werden Unten R ckweg abgeschaltet D mpfung 50 dB Mitte R ckweg pas...

Страница 3: ...chmesser des Kabel Innen leiters als 1 2 mm bzw Grat k nnen die Ger te buchsen zerst rt werden Durchmesser 0 6 1 2 mm gratfrei Max 2 mm berstand Anzugsmoment max 3 Nm Gefahr des berdrehens 10 dB aktiv...

Страница 4: ...erst rkung dB 14 22 Einstellbereich D mpfungs Einstellung dB 0 3 6 Max Betriebspegel 1 60 dB CTB CSO mit 8 dB Interstage Preemphase dB V 97 Rauschma dB 6 Anzahl der Ausg nge 1 R ckweg Frequenzbereich...

Страница 5: ...fiers from the mains is to unplug them Do not touch live parts The power plug must be easily operable as the means of cutting power to the amplifier meaning the wall outlet must be close to the amplif...

Страница 6: ...MHz 3 dB 0 dB 6 dB Bridging plugs to set the return path 5 65 MHz Both jumpers must be inserted in the same position Bottom Return path off attenuation 50 dB Centre Return path passive attenuation typ...

Страница 7: ...of burr the device sockets may be destroyed Diameter 0 6 1 2 mm burr free 2 mm distance max Tightening torque 3 Nm max Risk of overwinding 10 dB aktiv passiv aus aktiv passiv aus nur VOS 22 RA 3 0 6...

Страница 8: ...able attenuator setting range dB 0 3 6 Max operating level 1 60 dB CTB CSO with 8 dB interstage pre emphasis dB V 97 Noise figure dB 6 Number of outputs 1 Return path Frequency range MHz 5 65 5 65 Gai...

Отзывы: