background image

11 / 16

RF output level per digital TV channel

TV

channels

Opt. input at the receiver -8 dBm

Opt. input at the receiver -14 dBm

OEC 44 micro

OEC 40 micro

OEC 44 micro

OEC 40 micro

40

73 dBµV

78 dBµV

61 dBµV

66 dBµV

16

77 dBµV

82 dBµV

65 dBµV

70 dBµV

8

80 dBµV

85 dBµV

68 dBµV

73 dBµV

4

83 dBµV

88 dBµV

71 dBµV

76 dBµV

1

89 dBµV

94 dBµV

77 dBµV

82 dBµV

Information about the output levels of the OEC 40 micro or OEC 44 micro TV signal:
These levels are guidelines in an ideal scenario, assuming that all digital TV channels 
at the input are of the same level and no consideration has been taken of any possible 
frequency responses. In more specifi c individual cases the digital output level would need 
to be measured.

SAT

The typical SAT signal output level on the OEC 44 micro output is:
•  If the sum of all transponders has a total optical level of -14 dBm at the receiver input, 

the result for each channel is 59 dBμV at the output of the receiver (at 21 dB of optical 
attenuation and if 120 transponders are used).

•  If the sum of all transponders has a total optical level of -8 dBm at the receiver input, 

the result for each channel is 71 dBμV at the output of the receiver (at 15 dB of optical 
attenuation and if 120 transponders are used).

The typical SAT signal output level on the OEC 40 micro output is:
•  Transponders with an optical level of -14 dBm at the receiver input have a level of 

67 dBμV at the output of the receiver (at 21 dB of optical attenuation and if 120 tran-
sponders are used).

•  Transponders with an optical level of -8 dBm at the receiver input have a level of 

79 dBμV at the output of the receiver (at 15 dB of optical attenuation and if 120 
transponders are used).

•  These levels are guidelines in an ideal scenario, assuming that all TV channels at 

the input are of the same level and no consideration has been taken of any possible 
frequency responses. In more specifi c indvidual cases the output level would need to 
be measured.

FM and DAB+

The FM and DAB+ signal levels will be lowered by at least 10 dB in relation to the digital 
TV signal.

    

The signal level on the sockets must have the desired values as per EN 
60728-1 standard (stereo FM: 50-70 dBμV, DVB-T: 45-74 dBμV, 
SAT: 47-77 dBμV, digital cable TV: 47-77 dBμV, DAB+: 28-94 dBμV (Band 
III)). In certain cases, the RF output signal from the receiver or, if possible, the 
optical  input signal must be attenuated by the passive components, such as 
an optical attenuator.

Содержание OSC 100 micro

Страница 1: ...ransmitter OSC 100 micro and the optical receiver OEC 40 micro and OEC 44 micro can be used to distribute satellite and digital terrestrial signals FM DAB digital TV through a single mode fibre optic...

Страница 2: ...e with the local security standards and regulations The unit complies to protection class II and thus need not be connected to the protective earthing of the mains supply The safety regulations set ou...

Страница 3: ...high Terr opt on Fibre H low V low H high V high Terr 14V max 200mA Terr H high Test 205500005 LASER CLASS 1M Risk of material damage to the device If the inner cable conductor diameter is more than 1...

Страница 4: ...ptical distribution network make sure that the lasers of the connected transmitter have been switched off by disconnecting the mains plug Do not open the unit or tamper with it Under no circumstances...

Страница 5: ...st output SAT F type connector for the SAT test signal HH polarity RF level 60 dB V per transponder 5 Test output TV F type connector for the digital terrestrial signal 87 5 862 MHz RF level 74 dB V t...

Страница 6: ...bonding as per EN 60728 11 3 Optical input CLIK input Used for optical bre connection Outputs F type connectors 4 OEC 44 micro Terrestrial Sat Four combined outputs for FM DAB digital TV 87 5 862 MHz...

Страница 7: ...em Please use the Kathrein CLIKulator to plan and adjust your optical distribution network http clikulator com kathrein If directly connected without splitters or taps attenuators must be used between...

Страница 8: ...ssive OAC and OVC units as well as the suitable optical connectors ODC xxx Unused coaxial outputs must be terminated with an optical termination OTC 1 without fail Otherwise the proper functioning of...

Страница 9: ...be set to the same high level especially when multiple digital channels are transmitted As a guide the input signals should meet the following requirements 1 With QAM64 a maximum of 40 TV channels can...

Страница 10: ...onnectors must be terminated with EMK 03 with the exception of the 4 SAT inputs of the OSC 100 micro which due to DC voltage must be terminated with EMK 05 All unused optical connectors of the optical...

Страница 11: ...for each channel is 71 dB V at the output of the receiver at 15 dB of optical attenuation and if 120 transponders are used The typical SAT signal output level on the OEC 40 micro output is Transponde...

Страница 12: ...input level dB V 90 Test outputs Bandwidth MHz 87 5 862 1100 2150 HH polarity Connector type F type socket Output return loss dB 10 RF output level dB V 59 digital TV and Sat H H Optical output Conne...

Страница 13: ...ted voltage range V Hz 220 240 50 60 Operational voltage V mA 14 380 18 330 all outputs Power consumption W 3 3 5 Operating temperature C 5 to 45 LED information Power indicator Green LED Dimensions W...

Страница 14: ...GC of the OSC 100 micro optical transmitters ensures a constant optical output level independent of the number of digital terrestrial TV channels or the number of transmitted SAT transponders The sign...

Страница 15: ...irektanschluss am optischen Empf nger Koaxialkabel Glasfaserkabel Optischer Empf nger mit schaltbaren Ausg ngen OEC 40 micro 20550 0002 Fibre V low H low V high H high Terr Powe r OEC 44 micro 20550 0...

Страница 16: ...ww kathrein ds com support kathrein ds com 936500060 b STM 0221 GB Subject to change KATHREIN Digital Systems GmbH Anton Kathrein Str 1 3 83022 Rosenheim Germany Phone 49 731 270 909 70 For your notes...

Отзывы: