background image

935.543/

C

/

0707

/3.3e/ZWT

Internet: http://www.kathrein.de

KATHREIN-Werke KG  .  Anton-Kathrein-Straße 1 – 3  .  Postfach 10 04 44  .  D-83004 Rosenheim  .  Deutschland  .  Telefon (0 80 31) 1 84-0  .  Fax (0 80 31) 1 84-3 06

Abb. 6: Horizontal alignment

Abb. 7: Vertical alignment

Technical data of the antennas

Type

AOP 52

AOS 32

AOS 65

AOT 65

Order Number

212347

212349

212352

212353

Channels

21...52

21...32

21...65

21...65

Gain

dB

11...15

15,5...17

11...17

12...18

Reception range

MHz

470...726

470...566

470...830

470...830

Full width at half maximum

horiz.°

43...26

26...21

43...21

37...18

vert.°

52...32

30...23

47...23

39...19

Front-to-back-ratio

dB

24...30

27...31

25...32

23...32

Mast clamp range

mm Ø

22...60

Length

mm

1380

2830

2240

2820

Wind load at 800 N/m

2

N

108

203

179

192

Limiting wind load at 1100 N/m

2

N

148

287

246

263

Packing unit/weight

St./kg

1/2,3

1/3,8

1/3,5

1/3,7

Packing unit dimensions

mm

890 x 520 x 100

1080 x 520 x 130

960 x 520 x 130

1080 x 520 x 130

Overview of the Kathrein antenna masts

Type

ZSD 48

ZSF 47

ZSF 48

ZSH 47

ZSH 48

ZSH 59

ZSH 62

2

)

Order Number

218380

218385

218381

218386

218394

218382

218383

Lenght L

L/m

2 x 2 = 4

2 x 2,5 = 5

2 x 3 = 6

Diameter D

1

/D

2

D

1

/D

2

/mm

40/48

40/48

40/48

40/48

40/48

48/60

48/60

Cable entry points

3

-

3

-

3

5

5

Quality category (steel)

St 52

St 37

St 52

St 37

St 52

St 52

St 52

Wall thickness in clamping range

mm

2,5

2

2,5

2

2,5

2,5

4,5

Allowable bending moment 

1

),

5,0 m

-

-

-

320

850

1150

1950 

(1150)

Effective length at 800 N/m

2

4,0 m

-

500

1040

430

960

1280

2120 

(1280)

3,0 m

1170

540

1080

-

-

-

-

Allowable bending moment 1),

5,0 m

-

-

-

160

700

900

1700 (900)

Effectice length at 800 N/m

2

4,0 m

-

390

920

300

840

1080

1960 (1080)

3,0 m

1110

480

1000

-

-

-

-

Packing unit/weight

kg

1/11,4

1/11,3

1/14,2

1/13,1

1/17,8

1/20,5

1/37,5

1

)  The maximum allowable moment on the clamping point applies for the appropriate effectice length. The wind load absorption of the tube has already been allowed for. The 

bold values apply for an ordinary wind load (q = 800 N/m

2

). In case of increased wind load (q = 1100 N/m

2

), the reduced values apply.

  According to EN 50083-1, the mast clamping length must be at least 1/6 of the mast length.

2

)  The technical data underlie the computation base according to DIN 4131.

  If the sum of the antenna wind load moments exceeds the values put in parentheses (

 1650 Nm am Einspannpunkt), a structural analysis is required, according to EN 

50083, part 1.

Отзывы: