SAT measurement
29
Command Byte Menu
MSK 25 can send commands under DiSEqC™ 1.0 but cannot receive
them. All the commands requiring DiSEqC™ 2.0 (sending and receiving)
are underlined
grey
in the table below.
Commands in bold
are particularly preferred for KATHREIN switching
matrices.
Hex Byte
Command
Description
Numbe
r of
data
bytes
00
Reset
Reset DiSEqC™ Microcontroller
-
01
Clr Reset
Delete reset flag
-
02
Stand-by
Switching off peripheral power supply unit
-
03
Power on
Switching on peripheral power supply unit
-
04
Set Contend
Adjustment of contention flag
-
05
Contend
Feedback only if contention flag has been set
-
06
Clr Contend
Delete contention flag
-
07
Adresse
Feedback only if contention flag has not been set
-
08
Move C
Change address when contention flag has been set
1
09
Move
Change address when contention flag has not been set
1
10
Status
Read status register flags
-
11
Config
Read configuration flags
-
14
Switch 0
Read switching status flags (Committed Port)
-
15
Switch 1
Read switching state flags (Uncommitted Port)
-
16
Switch 2
Expansion option
-
17
Switch 3
Expansion option
-
20
Set LO
Calling up of low local oscillator frequency
-
21
Set VR
Calling up the vertical polarisation or clockwise circular
polarisation
-
22
Set Pos A
Select satellite position A
-
23
Set S0A
Select switchoption A
-
24
Set Hi
Calling up of high local oscillator frequency
-
25
Set HL
Calling up of horizontal polarisation or counter-clockwise
circular polarisation
-
26
Set Pos B
Select Satellitenposition B
-
27
Set S0B
Select switchoption B
-
28
Set S1A
Calling up of matrix S1 input A (input B inactive)
-
29
Set S2A
Calling up of matrix S2 input A (input B inactive)
-
2A
Set S3A
Calling up of matrix S3 input A (input B inactive)
-
2B
Set S4A
Calling up of matrix S4 input A (input B inactive)
-
2C
Set S1B
Calling up of matrix S1 input B (input A inactive)
-
2D
Set S2B
Calling up of matrix S2 input B (input A inactive)
-
2E
Set S3B
Calling up of matrix S3 input B (input A inactive)
-
2F
Set S4B
Calling up of matrix S4 input B (Eingang A inactive)
-
30
Sleep
All bus commands ignored, except „Awake“
-
31
Awake
Bus commands again accepted
-
38
Write N0
Setting Port Group 0
1
39
Write N1
Setting Port Group 1
1
3A
Write N2
Expansion option
1
3B
Write N3
Expansion option
1
40
Read A0
Read analogue value A0
-
41
Read A1
Read analogue value A1
-
48
Write A0
Set analogue value A0
1
49
Write A1
Set analogue value A1
1