Page 6
Output Power Uplink
Output Power Downlink
Each Compensator is individually tested and factory set to ensure FCC compliance and
cannot be adjusted without factory reprogramming or disabling the hardware. The
Compensator will amplify, but not alter incoming and outgoing signals in order to increase
coverage of authorized frequency bands only.
The Compensator only transmits signals if a wake up signal is and a signal from a mobile
phone is detected. The wake up signal is generated by the cradle only if a mobile phone
resides in the coupling tray.
If the Compensator detects an oscillation, it will automatically stop the transmission. For a
detected oscillation the Compensator will automatically resume normal operation after a
minimum of 1 minute. After 5 such automatic restarts, the Compensator shuts off until a
manually restart is initialized by taking the mobile phone off the cradle.
Noise power, gain and linearity are maintained by the Compensator´s microcontroller.
Parameter
Condition
Max.
Value
Unit
Pout
Uplink
Band 2
22
dBm
Band 4
22
dBm
Band 5
22
dBm
Band 12/17
22
dBm
Band 13
22
dBm
GSM
Band 2
24
dBm
Band 5
24
dBm
Parameter
Condition
Max.
Value
Unit
Pout
Downlink
Band 2
-27
dBm
Band 4
-27
dBm
Band 5
-27
dBm
Band 12/17
-27
dBm
Band 13
-27
dBm