3 / 8
Installation and Safety Instructions
Safety Instructions
WARNING
Danger to life from electric shock and fire hazard due to electric current!
Tampering with the unit may jeopardise its electrical safety. The manufacturer accepts
no liability for accidents caused by the user opening the unit. Opening the unit and
attempting to repair it yourself voids all warranty claims.
►
Do not open the device/power supply unit or tamper with it.
►
When working on the system, always unplug the mains plug from the wall socket.
►
Ensure adequate clearance. Clearance all round must be at least 5 cm.
►
Risk of overheating! Make sure there is free circulation of air to dissipate the heat
from the unit.
►
Do not place any liquid-filled items on top of the device/power supply unit.
►
Do not expose the device/power supply unit to dripping or splashing water.
►
Operate the device/power supply unit in the permissible ambient temperature
range of 0 to +40° C only.
►
Ensure that the power supply unit is easily accessible and usable.
►
Pull the plug out of the mains socket to completely disconnect the device/power
supply unit from the mains.
►
Install the device/power supply unit in dry indoor areas only.
►
Do not install on or against highly combustible materials.
►
Make sure that the device is equipped with an equipotential bonding conductor
(Cu, at least 4 mm
2
).
►
Make sure to comply with the safety regulations set out in the current EN 60728-
11 and EN 60065 standards.
Installation Instructions
►
Connectors for coaxial cables: RF connectors 75 Ω (series F) according to
EN 61169-24.
►
Only use the supplied bracket for the power supply unit.
►
Terminate unused F-type connectors with an EMK 05 (voltage-separated).
NOTICE
Risk of damage to property!
An inner cable conductor with a diameter greater than 1.2 mm, or the presence of
burrs may damage the device inputs/outputs beyond repair.
Max. 2 mm
excess
length
Clamping torque
3.4 Nm max.
(danger of over-
winding)
Diameter
0.6-1.2 mm free of burrs