background image

2 / 2

Quatro Universal Feed System, Switchable, Digital

Electronic equipment is not domestic waste - in accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT 
AND THE COUNCIL dated 27th January 2003 on used electrical and electronic appliances, it must be disposed of properly.
At the end of its service life, take this unit for disposal to an appropriate official collection point.

www.kathrein.com | [email protected]

KATHREIN-Werke KG, Anton-Kathrein-Straße 1-3, 83022 Rosenheim, Germany, Phone +49 8031 184-0, Fax +49 8031 184-52360

936.5047/-/VMPT/1015/GB | Subject to change.

Aligning the satellite reception system

To align the Kathrein Euroline satellite reception system, see the assembly instructions included in the scope of delivery of the para-
bolic antenna. If using satellite reception systems from other manufacturers, see the provided product documentation to align the 
satellite reception system.

Technical data

Type

Unit

KEL 444

Order no.

20110030

 

Suitable for parabolic antennas

KEA 650W/G/R, KEA 750W/G/R, KEA 850W/G/R

Polarisation

Switchable 4x (2 x horizontal and 2 x vertical)

Input frequency

GHz

10.70 – 11.70 and 11.70 – 12.75

Gain

dB

typ. 55

Output frequency

MHz

low band 950 – 1950

high band 1100 – 2150

Oscillator frequency (L. O.)

GHz

9.750

10.600

Polarisation decoupling

dB

min. 20

Output/impedance

-/Ω

4 x F-type connector/75

Supply voltage LNB

V

vert. (low band) 11.5 – 14.0 (0 kHz)/(high band) 11.5 – 14.0 (22 kHz)

hor. (low band) 16.0 – 19,0 (0 kHz)/(high band) 16.0 – 19.0 (22 kHz)

Power consumption LNB

mA

typ. 225

Feed fixture dimension (Ø)

mm

40

Dimensions with cap

mm

131 x 63 x 108

Weight, approx.

kg/St.

0.34

Warranty conditions

• 

The warranty only covers replacement of the product.

• 

The LNB must be installed by qualified personnel in compliance with the enclosed instructions.

• 

Do not modify the LNB, e.g. by drilling.

• 

Do not cause any mechanical damage to the LNB, e.g. deformations caused by falling from a roof.

• 

Do not cause any chemical damage to the LNB, e.g. due to exposure to solvents, lacquers, detergents or the like.

• 

Furthermore, the warranty does not apply to damage caused by force majeure, e.g. lightning, storm or hail.

• 

Only the original invoice is acceptable for warranty claims.

Service centre

If, contrary to expectation, you should have any problems with Kathrein Euroline quality products, please contact your specialist 
dealer or our service centre. The address of our service centre is:

REP and MORE GmbH

Hauptstr. 2a, 35792 Löhnberg-Obershausen
Phone: +49 6477 6123-101, Fax: +49 6477 6123-020

KEL 444

 

20110030

Отзывы: