background image

3

General

1. Features

Q

Facilitates the use of the USW 30 control software

Q

Required on the use of certain functions for some channel units, e. g. for NIT generation

Q

Can be used to update older UFO

®

compact 

systems

Q

Control of individual channel units using UFO

®

compact

 controller (from software version 9.20) or

PC with control software USW 30 (version 3.2)

Q

Feature for remote maintenance over LAN as well as analogue, ISDN or GSM modem

Q

Up to eight UFX 314 can be confi gured over LAN to form a group

Q

Up to 256 groups can be controlled independently of each other in a LAN segment

The UFX 314 data bus de-multiplexer (BN 20610071) is used for the central control of all channel units installed in 
a UFG 412 base unit. Each channel unit is connected using a separate cable. Several demultiplexers can be con-
nected to a system over a network.

Содержание BN 20610071

Страница 1: ...User manual UFX 314 data bus de multiplexer BN 20610071...

Страница 2: ...ller 7 3 3 Network configuration 7 3 4 USB installation 8 3 4 1 Microsoft Windows 8 3 4 2 Linux 11 4 Software Update 11 5 Web interface 5 1 The main page 12 5 1 1 The device group box 12 5 1 2 The sys...

Страница 3: ...control software USW 30 version 3 2 Q Feature for remote maintenance over LAN as well as analogue ISDN or GSM modem Q Up to eight UFX 314 can be configured over LAN to form a group Q Up to 256 groups...

Страница 4: ...l UFX 314 and a control PC 2 3 status LEDs The Power LED illuminates as soon as the UFX 314 is supplied with power The status is indicated using the Error LED and Event LED The Event LED illuminates d...

Страница 5: ...14 The modem operates independently of the demultiplexer to which it is connected Q Now push the demultiplexer into the 1 HU front unit from the front and screw into place Q Then connect the power sup...

Страница 6: ...6 483 44 1HE 355 8HE Ka na l z ug 1 Ka na l z ug 12 Ka na l z ug 12 Ka na l z ug 1 Channel unit 1 Channel unit 12 Channel unit 1 Channel unit 12...

Страница 7: ...nf Microsoft Windows also uses this method if a fixed IP address has not been defined and a DHCP server is not available The related standard was published by the IETF under RFC 3927 1 The devices in...

Страница 8: ...PC and restart it using the Reset button Before reconnecting to the PC wait until the demultiplexer has started completely see 2 3 Status LEDs After the UFX 314 is connected a wizard for installing ne...

Страница 9: ...o take any further steps Otherwise double click the network symbol in the task bar or select the respective network connection name USB Ethernet RNDIS in the Control Panel under Network connections Im...

Страница 10: ...10 Click Properties Select Internet Protocol TCP IP and then click Properties...

Страница 11: ...tion then save the update archive on a USB stick The name of the file on the stick must start with UFX314_ and have the same ending as the file in the bundle e g tar gz Should the bundle contain sever...

Страница 12: ...re already on the main page for a unit the related links are not available After the serial number there is a schematic diagram of the demultiplexer The diagram is divided into three parts The three s...

Страница 13: ...velo formerly Elsa Microlink 56k Fun II Analogue MicroLink ISDN i ISDN 3Com US Robotics Sporster Flash Analogue Siemens MC 35 GSM The modem installed must be set to a speed of 115200 Baud or to automa...

Страница 14: ...Select here Connect to the Internet and then click Next Now select Set up my connection manually After selecting Connect using a dial up modem use Next to open the dialog box for the connection s nam...

Страница 15: ...and password as you have set using USW 30 A check mark must also be set at Make this the default Internet connection If you have not entered a password using USW 30 or have entered a blank password th...

Страница 16: ...the connection in future directly from the desktop Otherwise you will find the connection in the network connections where you have just opened the wizard This window always appears when you want to e...

Страница 17: ...are using an ISDN modem click Configure Otherwise select the Security tab With an ISDN modem you must change the Modem protocol setting to V 120 64k After accepting your changes using OK select the Se...

Страница 18: ...d then click Settings to change the advanced security settings In this dialog box select as Data encryption No encryption allowed and then Allow these protocols Only Unencrypted password is to be sele...

Страница 19: ...rface such as KPPP It should be noted that all modems currently available with a USB interface have been primarily developed for Windows and they may therefore be difficult or impossible to use with L...

Страница 20: ...ox Click Add to open a dialog box for entering the demultiplexer s telephone number On the other tabs you can leave all the default settings The default settings should be as follows IP Dynamic IP add...

Страница 21: ...w Assign a name to your modem and select the appropriate connection in Modem device Ensure the speed is not too high On the Modem tab you can poll the modem to check whether you have selected the righ...

Страница 22: ...Name Version Licence Linux Kernel 2 6 22 1 GPL Das U Boot 1 1 4 GPL Bridge utils 1 2 GPL Busybox 1 2 1 GPL betaftpd 0 0 8pre17 GPL libstdc 6 0 4 GPL with exception glibc 2 3 5 LGPL linuxthreads 0 10 L...

Страница 23: ...niversity http www cmu edu computing 7 3 Acknowledgements If you have any questions related to the open source software included or to order the source code contact the following address KATHREIN Werk...

Страница 24: ...nternet www kathrein de KATHREIN Werke KG Anton Kathrein Stra e 1 3 P O Box 100 444 83004 Rosenheim GERMANY phone 49 8031 184 0 Fax 49 8031 184 306 936 3429 A 1008 ZWT Technical data subject to change...

Отзывы: