936.4054/b
.1
Subject to alteration.
86010149
Page 1 of 2
Integrable Remote Control Unit (iRCU)
Type No.
86010149
Protocols
Compliant to AISG 1.1 and 3GPP/AISG 2.0
Logical interface ex factory
1)
AISG 2.0/3GPP
Input voltage range
10 ... 30 V (pin 1, pin 6)
Power consumption
< 1 W (stand by); < 10 W (motor activated)
Connectors
2)
2 x 8 pin connector according to IEC 60130-9; according to AISG
Daisy chain in: male; Daisy chain out: female
Hardware interfaces
RS 485A/B (pin 5, pin 3);
power supply (pin 1, pin 6); DC return (pin 7);
according to AISG / 3GPP
Adjustment time (full range)
40 sec (typically, depending on antenna type)
Adjustment cycles
> 50,000
Temperature range
–40 °C … +60 °C
Protection class
IP 24
Lightning protection
AISG interface (each pin);
2.5 kA (10/350µs); 8 kA (8/20µs)
Weight
480 g (1.1 lbs)
Packing size
245 x 93 x 102 mm, (9.6 x 3.6 x 4 inches)
Dimensions (H x W x D)
170 x 68.5 x 66 mm, (6.68 x 2.7 x 2.6 inches)
1)
The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 and vice versa
with a vendor specifi c command.
Please note:
If the Primary of the RET system doesn’t support the standard of the ‘logical interface ex factory’, the
iRCU must be switched to the appropriate standard of the Primary before installation. Please contact
Kathrein for further information.
2)
The tightning torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector
should be tightened by hand only!
Standards
EN 60950-1 (Safety)
EN 55022 (Emission)
EN 55024 (Immunity)
ETS 300019-1-4 (Environmental)
Certifi cation:
CE, FCC15.107 class B
Scope of supply: Integrable Remote Control Unit
Kathrein’s 86010149 integrable Remote Control Unit (iRCU) allow operators to control the
electrical tilt of compatible antennas without direct access to the antenna.
•
Compliant to AISG 1.1 and 3GPP/AISG 2.0
•
Field replaceable without dismantling the antenna
•
Daisy Chain feasibility
•
Allow control of the antenna either locally through a laptop computer, on site desktop compu-
ter, the optional central control unit; remotely via an ethernet network or over the internet
Daisy chain in
(male)
Daisy chain out
(female)
Retaining Screw Torx 20
Bottom view of RCU
170 (6.68˝)
14.6 (0.57˝)
17.4 (0.68˝)
66 (2.6˝)
49.5 (1.45˝)
59.5 (2.34˝)
68.5 (2.7˝)
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com
Downloaded from
Downloaded from
Downloaded from