![Kathrein 20510142 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/kathrein/20510142/20510142_manual_657837015.webp)
7 / 8
Type
EXD 158 Twin
EXD 258 Twin
Order no.
20510142
20510143
Subscriber connections
2 x 8
2 x 8
Inputs
1 x terr.
4 x Sat
1 x terr.
4 x Sat
Frequency range
MHz
5 – 862
950 – 2150
5 – 862
950 – 2150
Through loss
dB
-
-
3
1.5
Connection loss (terrestrial)
dB
11
-
11
-
Sat (AGC) output level
dBµV
-
94
-
94
Horiz./vert. decoupling
dB
-
30
-
30
Trunk decoupling
dB
-
-
-
40
Sat input level
dBµV
-
60 – 90
-
60 – 90
Subscriber frequency/user band
MHz see
Frequency Assign-
ment, p. 4
see
Frequency Assign-
ment, p. 4
Permissible supply voltage at the
subscriber output
V
12 – 14
12 – 14
Max. current consumption at the
subscriber connection
mA
20
20
(With power supply unit)
450
(without power supply unit)
Max. permissible voltage at the
subscriber connection
V
19
19
Max. permissible remote feed current
(horiz. low input)
mA
500
-
Max. permissible remote feed current
per trunk
mA
-
1000
Max. supply voltage at DC connection
V
18.6
18.6
Protection class
IP 30
IP 30
Permissible ambient temperature
°C
-20 to +55
-20 to +55
Connections
F connectors
F connectors
Dimensions
mm
102.8 x 148 x 44
111.5 x 148 x 44
Packing unit/weight
pc./kg
1 (10)/0.51
1(10)/0.4
Power supply unit NCF 18
Order number
20510067
Nominal input voltage
V
230 (47 – 63 Hz)
-
Permissible input voltage range
V
207 – 253
-
Nominal input power at 0/150/500 mA
load*)
W
5.4/8.7/15.5
-
Secondary voltage (DC)
V
18
-
Protection class/protection type
II (double insulated)/IP30
*
)
All user bands in operation
Possible Causes of Failure and Troubleshooting
There are two LEDs near the bottom subscriber connection to be able to narrow down causes of
failure (installation assistance):
LED colour
Signal
Description
Green
LED is on
The LNB is powered
Red
LED is fl ashing
The multi-switch has received and understood
the single-cable command
Technical Data