background image

 

16 

 

 

7.3 

Examining the filter elements 

 

Examination of the thickness of the ceramic wall must be done with the measuring gauge provided. As

 

soon as the gauge can be pushed over the ceramic, it means it has reached its minimum thickness,

 

and the filter element must be replaced. In addition, elements showing signs of cracks must also be

 

immediately replaced. 

 
 
 

 

7.4 

Troubleshooting Guide 

 
 

 

Problem

 

Possibilities

 

Solution

 

Filter delivers low water quantities 

 

Dirty filter element 

Clean the filter element 

Valve is closed 

Turn the valve to a horizontal position 

Sampling valve open 

Close the sampling valve 

Pump unit delivers too little water 

Motor is not running at the max speed 

Suction filter not completely covered in 
water

 

or dirty 

Optimize the suction 
filter.

 

Clean the filter. 

Suction filter positioned 
poorly

 

(e.g. in sediment) 

Optimize the suction 

filter’s position. 

Loss of pressure in the filter system 

Check the entire MOT-7 system 
for

 

water leakage 

Unsatisfactory water quality 

Filter element broken 

IMMEDIATELY replace the 
filter

 

element 

Filter element needs replacing 

IMMEDIATELY replace the 
filter

 

element 

Filter element has hairline cracks 

IMMEDIATELY replace the 
filter

 

element 

 
 

 
 
 
 

 

Contact information  

 
 
 

Katadyn Products Inc. 
Pfäffikerstrasse 37 
8310 Kemptthal 
Switzerland 
Tel +41 44 839 21 11 | Fax +41 44 839 21 99 

[email protected]

 

www.katadyngroup.com

 

 
 

 

Содержание MOT-7

Страница 1: ...1 MobileMicrofiltrationSystem MOT 7 Water treatment with Katadyn ceramic filters...

Страница 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 7 8 4 1 Setup Procedure 9 5 1 Setup procedure 10 6 1 Brief description of the handle position of operational compone...

Страница 3: ...eral Safety Guidelines The mobile Microfiltration System MOT 7 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Страница 4: ...in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other materi...

Страница 5: ...safety operations and maintenance instructions and improper repairs Improper use of the MOT 7 use not in compliance with instructions Use of repair parts not permitted by the MOT 7 manufacturer Opera...

Страница 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Страница 7: ...ments become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly unde...

Страница 8: ...resh water outlet Drain water outlet Cleaning hose connection hose is enclosed Sample valve outlet 3 7 Flow rates of the MOT 7 The above chart shows the typical performance of the unit when operated i...

Страница 9: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Страница 10: ...ice 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and screw them hand tight in...

Страница 11: ...11 Hook up the cleaning hose to the corresponding threads The MOT 7 is now ready for use...

Страница 12: ...t Valve B Sample Valve E Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slight...

Страница 13: ...g 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 7 must be set in the operational mode see chapter...

Страница 14: ...lve D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the p...

Страница 15: ...the Pump Open cleaning valve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Repla...

Страница 16: ...se the sampling valve Pump unit delivers too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suc...

Страница 17: ...t Number Description Picture 7010719 V Band Clamp M MOT7 MF 7 20621 SET Cleaning Hose M MOT7 complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elemen...

Страница 18: ...tadyn Filter element No 5 128031 O Ring Seal 268 x 16mm 7010633 Suction Hose M MOT7 incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze Option for difficul...

Отзывы: