TROUBLESHOOTING

Close pressure relief valve

SYMPTOM

CAUSE

REMEDY

No freshwater

Salty product water

No water rejected or produced 

Motor/Piston Not Moving

Cables not plugged in properly

Intake out of water

Pressure relief valve not sealed

System needs time to stabilize

Solar not providing enough power

Intake filter blocked/too dirty

Air bubble in watermaker

Handheld test read inaccurately

Unplug all cable connections, then plug back in. Check cable ferrules are properly 
inserted into DC/DC converter.

Orient solar panels perpendicular to sun rays or switch to another power supply

Place pre-filter back in water or change location of adjustable hose weight

Unscrew old intake filter and screw on provided second filter or clean by spraying water

While running, tilt the watermaker to the left 30° then to the
right 30°. Repeat 4 times. 

Sample water regularly for up to 45 minutes

Ensure 

x10

 is not seen in corner of window

HFD-PS40 Land Warfare Universal Watermaker

Quickstart Guide 