moisture removal). The fire insulation on the steam room floor must extend a distance of 400 mm 
(16”) beyond the front of the heater, 250 mm (10”) on both sides and 250 mm (10”) in the rear, or 
up to an insulated wall on the sides and in the rear.  As far as fire insulation on the fire door side 
is concerned, also consider the instructions given in section 2.3. 

If you are uncertain, consult the local building authorities. 
 
 
2.5. INSTALLATION IN A BRICK CHIMNEY

 

The heater can be connected to a brick chimney from the rear or at the top. To do so, make a hole in 

the chimney 2 to 3 cm (3/4 - 1 3/16”) wider than the connecting flue pipe. Seal the gap with an 
elastic  non-combustible  material,  such  as  fireproof  wool.  Cover  the  hole  with  the  Kastor  cover 
plate available from your local hardware dealer. Use metal fixings to fasten the cover plate to the 
brickwork.

 

When the connection is made in the rear, use a screwdriver to remove the plate covering the hole in 

the rear mantle and use it to close the hole at the top of the heater. Install the connecting pipe 
supplied to the heater and push the heater in position while ensuring that the connecting pipe fits 
snugly in the hole made in the chimney. Seal the gaps as explained. 

The connection to a brick chimney at the top of the heater is made using a 45° angle section that can 

be  turned  to  a  suitable  position  in  respect  of  the  chimney  (an  extension  pipe  can  be  used  if 
necessary).  First  insert  the  heater’s  exit  flue  pipe  then  place  the  angle  section  on  top  of  it.  If 
necessary, the angle section

 and any extension pipe can be sawn to required length. Seal and

 

cover the gap between the pipe and chimney as explained. 

Follow the safety instructions given in section 2.3 and the brick-laying instructions for chimneys. 

 
2.6. INSTALLATION USING THE KASTOR MODULAR CHIMNEY  

(Not available in the U.S. market)

 

A Kastor heater can be connected to a prefabricated modular Kastor chimney. Be sure to select the 

right size of chimney with due regard to heater model, chimney height, ambient conditions, etc. 
To ensure optimum performance, always use a flue damper. 

x

 First insert the heater’s exit flue pipe.  

x

 On top of that, place a non-insulated connecting pipe and extension pipe if required. The connecting 

and extension pipes can be sawn to required length. The flue damper is installed at the lower end 
of the chimney. 

x

 Then continue with insulated chimney modules. The insulated part of the chimney must extend down 

to a height of 400 mm (16”) below the ceiling. Follow the chimney instructions. 

Follow the safety instructions. 

Kastor Oy cannot guarantee the suitability and performance of chimneys from other manufacturers for 

use with Kastor sauna heaters and naturally accepts no liability for their quality. 

 
2.7. VENTILATION OF THE SAUNA 

Gravity ventilation in the steam room: 
Provide an air inlet opening of 70–140 cm

2

 (27 5/16 – 54 5/8 in

²

) next to the heater near the floor level. 

A 2 cm (13/16”) air gap between the steam room door and door frame is enough. An air outlet 
pipe of the same size, preferably adjustable, can be provided under the upper bench opposite to 
the heater, at least 1 m higher than the air inlet opening. 

Mechanical ventilation in the steam room: 
Provide an air inlet opening of 70–140 cm

²

 (27 5/16 – 54 5/8 in

²

) next to the heater near the floor level 

or above the heater at a height of about 50 cm (19.5”) from the stones. A 2 cm (13/16”) air gap 
between  the  steam  room  door  and  door  frame  is  enough.  An  air  outlet  pipe  of  the  same  size, 
preferably  adjustable,  can  be  provided  under  the  upper  bench  opposite  to  the  heater.

  Please 

note that the steam room air vents must made of metal! 

 

2.8. FIRE DOOR 
 
2.8.1 ADJUSTABLE LEFT OR RIGHT HAND SWING 

To change the swing of the door, turn the fire door the other way round. 

x

 Open the fire door and push the hinge pin out through the bottom hole. 

x

 Pull the top pin downwards to detach the door. Do not forget the washers.  

x

 Turn the door upside down so that the handle is on the side where you want to have it. 

4211-60  

Kastor K-007, KL16VE 

3/25/11 

 

 

Rev. 1 

Содержание K-007

Страница 1: ...chosen a KASTOR product for your fireplace Fireplace hearts from KASTOR are renowned for their high quality and long life SAVE THESE INSTRUCTIONS After installation these instructions must be given to...

Страница 2: ...over or the scoop can cause the water to boil over abruptly 2 INSTALLATION 2 1 PREPARATIONS x Place the sauna heater without stones and water tank or with the water tank filled with water if applicabl...

Страница 3: ...to a minimum distance of 400 mm 16 forward The protective sheeting must consist of a metal sheet with a minimum thickness of 1 mm 3 64 See also section 2 4 2 4 INSTALLATION BASE Install the sauna hea...

Страница 4: ...ey Be sure to select the right size of chimney with due regard to heater model chimney height ambient conditions etc To ensure optimum performance always use a flue damper x First insert the heater s...

Страница 5: ...t seal 1 onto the threaded section of the tap x Insert the tap into the hole in the heater mantle x Insert seal 2 onto the threaded section of the tap inside the mantle x Lift the water tank in positi...

Страница 6: ...ways use natural untreated wood preferably solid birch or alder cut to a length of one third of a meter 12 Wet or rotten wood does not produce much heat Never burn impregnated wood wood containing nai...

Страница 7: ...e sustained at the right level for a long time When going to the sauna you can add a couple of logs if necessary 3 8 CLEANING THE HEATER REMOVAL OF ASH AND CHIMNEY SWEEPING To wash the exterior of the...

Страница 8: ...capacity see selection guide Keep the vent open to let excessive heat escape to allow the stones to heat up in the process In this way the time required for heating is slightly longer 21 Is the heati...

Страница 9: ...8 07 4211 60 Kastor K 007 KL16VE 9 3 25 11 Rev 1...

Страница 10: ...8 07 4211 60 Kastor K 007 KL16VE 10 3 25 11 Rev 1...

Страница 11: ...8 07 4211 60 Kastor K 007 KL16VE 11 3 25 11 Rev 1...

Страница 12: ...8 07 4211 60 Kastor K 007 KL16VE 12 3 25 11 Rev 1...

Страница 13: ...n insulated connecting pipe from above when connecting to combustible material from connecting pipe surface to the side 1000mm 40 upwards 1200mm 48 B The stove s distance from combustible material to...

Страница 14: ...8 07 4211 60 Kastor K 007 KL16VE 14 3 25 11 Rev 1...

Отзывы: