10
7.
Operation method and precautions for the charger
(1)
Operation method:
①
During charging, insert the battery box plug firstly, and then insert the commercial electricity
AC220V plug. After charging, firstly remove the commercial electricity AC220V plug, and then
remove the battery box plug;
②
During normal charging, the charger indicator lamp will show red; after full charging, the charger
indicator lamp will show green;
③
If the charging temperature is too high, the red lamp will flash and the charger will be in a
temperature protection state. Please move the charger to a cool and ventilated place. When the internal
temperature of the charger reaches 60
℃
, recover normal charging.
④
If no battery is connected during use, the charger output is the pulse voltage smaller than 42V.
During the test, apply 1KΩresistance load between positive and negative output terminals, and the
actual charging voltage of the charger can be tested.
(2)
Precautions
①
The charger can only be used indoors.
②
No charging can be carried out in the sealed space or under the scorching sun and high temperature
environment. The charger can’t be placed in the seat cask or the trunk for charging.
③
It is not allowed to connect the noload charger with AC power supply for a long time under the
uncharging state.
④
If the indicator lamp is abnormal and becomes smelly or the charger shell is overheated during
Содержание Citycoco
Страница 1: ...Product specification...
Страница 19: ...17 Speed regulation Left and right brake cranks Chapter V Electric Principles S1 electric switch Hall device...